Jandy AquaLink RS Installation manual - page 21
21
Basic Programming.
To set a particular piece of equipment to turn on and off at
predetermined times, highlight EQUIPMENT ON/OFF and press select.
To highlight an item, use the up or down buttons. Use the SELECT
button to turn the equipment on or off. After turning a piece of equipment
on, return to the main menu by using the back button. Repeat this
process for each piece of equipment that you wish to program. You may
enter as many programs as needed for each piece of equipment.
Set the Time.
To set the time, highlight MENU/HELP press select, highlight SET TIME
and press select. Use the arrow keys to set values, press SELECT to
continue.
The following items can be found either in the MENU/HELP or in a Sub
Menu under SYSTEM SETUP:
Set the Temperature.
To set the pool and spa thermostats, highlight MENU/HELP press select,
highlight SET TEMP and press select. Use the arrow keys to highlight
either pool or spa and press select. Use the arrow keys to increase or
decrease the temperature.
Label Auxiliary Functions.
To label Auxiliary functions, highlight MENU/HELP press select,
highlight SYSTEM SETUP press select, highlight LABEL AUX and press
select. You can choose a name from general, light or waterfall labels or
enter a custom name by using the arrow keys to change letters and
using the select key to move to the next letter.
Set Spa Side Switch or SpaLink RS Functions.
To set the Spa Side Switch or SpaLink RS, highlight MENU/HELP press
select, highlight SYSTEM SETUP press select, highlight SPA SWITCH or
SPA LINK and press select. Highlight the number of remotes you have
and press select. Use the arrow keys to move the highlight bar to choose
which button you are assigning, press select. Use the arrow keys to
move the highlight bar to choose which piece of equipment will be
associated with the button, press select. After pressing select on the
piece of equipment, you will be returned one screen to continue
assigning Spa Side Switch or SpaLink RS buttons.
Set Freeze Protection.
To set freeze protection, highlight MENU/HELP press select, highlight
SYSTEM SETUP press select, highlight FREEZE PROTECT and press
select. Use the arrow keys to change temperature. Once the temperature
is set use the select button to move to the next screen to assign freeze
protection to a selected piece of equipment. Note: the filter pump is
always assigned to freeze protection.
Assign JVAs.
To assign JVA's, highlight MENU/HELP press select, highlight SYSTEM
SETUP press select, highlight ASSIGN JVAs and press select. Highlight
the JVA you wish to assign and press select.
OneTouch Control Panel Programming and System Defaults
Default Temperature
Default Pool Temp - 80ºF.
Default Spa Temp - 102ºF.
Default Temperature
Default Freeze Protect. Settings
NOTE: If you select
SPA
to be freeze protected,
water circulation will switch between pool and spa
every 30 minutes during freezing conditions once
freeze mode is active.
FILTER PUMP: Freeze Protection ON. ALL OTHER
EQUIPMENT, Freeze Protection OFF.
Default Time - 1:00 P.M.
Default Day - MONDAY
Default Date - 01/31/00
Default Time
KEY HELP
PAGE UP
PAGE DOWN
BACK
UP
DOWN
CONTINUE