NEC DS2000 IntraMail Product Description - page 114
Section 4: Specifications and Parts List
106
◆
Section 4: Specifications and Parts List
DS1000/2000 Product Description
Cabling Requirements
•
Do not run station cable parallel with the AC source, telex or computer, etc. If the
cables are near cable runs to those devices, use shielded cable with grounded
shields or install the cable in conduit.
•
When cables must be run on the floor, use cable protectors.
•
Cable runs for key telephones, single line telephones and Door Boxes must be a
dedicated, isolated cable pair.
Device
Cable Type
Cable Run
Length (ft.)
Notes
Key Telephone &
Digital Door Box
2-wire 26 AWG
2-wire 24 AWG
DS2000: 1300
DS1000: 650
DS2000: 2000
DS1000: 1000
Single Line
Telephone
2-wire 26 AWG
DS2000: 11,500
DS1000:8000
at constant 20 mA
2-wire 24 AWG
DS2000: 18,000
DS1000:12000
at constant 20 mA
2-wire 22 AWG
DS2000: 29,000
DS1000:16000
at constant 20 mA
Analog Door Box
(DS1000 Only)
2-wire 24 AWG
2-wire 22 AWG
330
550
2-OPX (DS2000
Only)
2-wire 24 AWG
1000