Northern DVRN960 Series Setup Manual - page 7
7
Dome Camera Control
Dome Camera Connection & Settings:
See section Pin Definition of Alarm I/O & RS-485, and Audio for RS-485 port pin definition.
Refer to the following figures. Connect the R+, R- terminals on the dome camera to the RS-485
D+, D- terminals on the DVR by RS-485 cable respectively.
4CH models:
8CH models:
16CH models:
To set up the dome protocol and ID of the camera, press
MENU
to access the OSD main menu,
and select
Camera
>. Then select
Dome Protocol
> and choose the corresponding protocol.
Next, select
Dome ID
> and choose a preferred ID number. Note that the ID number must
match the ID address defined by the dome camera.
To configure the RS-485 parameters, select
System
> from OSD main menu, and then select
RS485 Setup
>. The default
RS-485 settings are 9600 Baud, 8 Data Bits, 1 Stop Bit and No
Parity.