Novar ED&S Response PL4 Installation Manual - page 12
- 12 -
★ Different timer settings for the strobe/siren can be programmed (ref Section 4.10)
★ Connect the two x 2 cores cable (2 for signal, 2 for tamper) to the terminals inside the siren,
ensure you mark up one of the 2 core sets so you know which one corresponds to the tamper
and which one to the power (DC IN) terminals in the control panel, then pass through the 2 x
2 core cables through the wall, and connect the other end of the cable to the corresponding
terminals in the Control Unit. See Illustration 3 on page 8.
★ Remove the pre-link jumper at TAMP terminal in control panel to activate the tamper
function for external siren.
★ Replace cover on siren and refit retaining screw.
3.5 Testing the System
★ After installation is completed, plug in the main power supply adaptor. The “POWER”
indicator will illuminate and the “OFF” mode LED (green) will also light up, showing the
system is in “OFF” mode. Wait about two minutes for the system to get ready.
Testing the detectors
With the system in “OFF” mode (“OFF” mode LED illuminated),
press “*”, “6”, “1”, “#”.
Two short beeps acknowledge acceptance of command and walk test mode
activated.
Trigger all the detectors (magnetic contacts and PIRs) one by one. The corresponding zone
indicators on the Control Unit should light up.
If the zone indicator does not light up, check the corresponding detector and wiring. Fix the
problem and test again.
Exit walk test mode by pressing “*”, “6”, “#”. Two short beeps with zone indicators turned
off indicate walk test mode exited.
Repeat the test periodically where necessary.
Testing the external siren & strobe
Use the Panic Alarm command (pressing “*” and “#” simultaneously) to trigger the alarm
for testing. The built-in siren in the Control Unit will sound immediately with all four zone
indicators illuminated and the external siren will sound 30 seconds later. The alarm sound
will stop automatically after 3 minutes (factory setting, alarm duration timer is adjustable).
To stop the alarm sound & flash, enter User PIN at the Control Unit. To clear the zone
indicators, enter “*”, “8”, “#”.
External Siren duration
Programming Key at
Control Unit (with
the
system
in
“OFF” mode)
Internal
Siren
(in Control
Unit) duration
Strobe duration
Jumper Setting
on (1 Minute)
Jumper Setting
on (3 Minutes)
Jumper Setting
on (10 Minutes)
1.
Approx. 3
minutes
Flash
continuously
until the User PIN
Code is entered at
the Control Unit
Approx.1
minute
Approx. 3
minutes
Approx. 10
minutes
2.
Approx. 1
minute
Approx.1
minute
Approx. 1
minute
Approx. 1
minute
Approx. 1
minute
3.
Approx. 3
minutes
Approx. 3
minutes
Approx. 1
minute
Approx. 3
minutes
Approx. 3
minutes
4.
Approx. 10
minutes
Approx. 10
minutes
Approx. 1
minute
Approx. 3
minutes
Approx. 10
minutes
Important: If the Security System has been reset to factory default settings (Reference: instruction manual page
17) please activate the above strobe/siren alarm hold duration timer command again.