Novar ED&S Response PL4 Installation Manual - page 3
- 3 -
1.3 Tools Required
The following tools are required for installation:
★ Large & small flat bladed screwdrivers and cross point screwdrivers
★ Hammer
★ Power drill
★ Drill bits – 4mm & 6mm
★ Wire cutters and wire stripper
★ Eye protection (recommended when using a power drill or hammer)
1.4 System Features
★ Simple and effective Four-zone system with the new two-wire technology.
★ All system components (sensors, sirens) are connected to the Control Unit via two-core
non-polarity flat wires. Wiring and installation of the system is extremely simple and easy.
★ Control Unit has built-in keypad with status LEDs and zone indicators. Low battery and
tamper attempts will be indicated by the status LEDs.
★ Push-button “HOME”, “OUT” and “OFF” three mode operation.
★ “HOME” and “OUT” modes are pre-programmed for user convenience.
★ At “OFF” mode, door chime function is available.
★ All sensors, sounders are 24 hour line-protected and fully supervised. Any attempt to interfere
with the system, such as cutting the connecting wires or opening any of the PIR detectors,
will trigger the alarm and be identified by flashing LEDs and zone indicator.
★ No fuse to burn. Short-circuit tamper attacks to any zone sensor will trigger the alarm and be
identified by flashing LEDs and zone indicator, but the operation of the rest of the system is
protected.
★ Two User PINs allocated for disarming (unsetting) the system.
★ Individual zones can be set to “HOME-BYPASS” or “BYPASS”; for example, the up-stairs
detectors can be set to “HOME-BYPASS” at night.
★ Two PIR motion detectors can be connected to one zone, therefore the system can be
expanded to have four PIRs plus many magnetic contacts.
MOVEMENT DETECTOR
PASSIVE INFRA-RED (PIR)
CONTROL UNIT
DOOR/WINDOW
CONTACTS
EXTERNAL SIREN & STROBE
15VAC ADAPTOR