Pacific Energy NEO 1.6 Installation And Operating Instructions Manual - page 14
14
NEO 1.6 INSERT-A
050515-24
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
Surround Assembly and Installation
1) Attach the surround back to the surround mounting brackets
on the unit with the four screws provided.Fig. #7
2) Push the entire appliance back until the surround assembly
is in contact with the fi replace.
3) Attach the front surround by inserting the surround hooks
into the slots in the front surround mounting bracket, be-
tween the blower bracket and the fi rebox, on both sides
and sliding down to engage the hooks onto the brackets.
Fig. #8
Fig. # 7
Fig. # 8
Combustion Air
Consult local building codes regarding combustion air supply.
Intake or combustion air can be supplied to the Insert in one
of two ways:
1) Outside air supply: Remove cover from ash clean out in
existing fi replace. Place a rodent screen in place of the
cover. Install the Insert as described in the "Installation"
section, making sure not to cover the opening of the air
inlet. When installation is complete, seal the back surround
to fi replace. This will ensure combustion air is drawn from
outside the house and under the unit.
2) Room air supply: The unit must have adequate air for
combustion provided in the room the unit is installed in.
This may involve providing make up air from outside the
house.
SURROUND MOUNTING BRACKETS
F RO N T S U R RO U N D
MOUNTING BRACKET
HOLES
SURROUND HOOKS
f i r e - p a r t s . c o m