Pacific Energy NEO 1.6 Installation And Operating Instructions Manual - page 3
050515-24
NEO 1.6 INSERT-A
3
©PACIFIC ENERGY FIREPLACE
PRODUCTS LTD.
16”
406mm
18”
457mm
9
3/4
”
248mm
13 1/2”
343mm
8”
203mm
Clearances
Masonry or Factory Built Fireplace
The minimum required clearances to surrounding combustible
materials when installed into a masonry or factory built fi replace
are listed below and in Fig. #1.
Minimum Clearances to Combustibles
Adjacent Sidewall................................... 13 1/2 in. (343 mm)
Mantel(measured from top of brow) .............16 in. (406 mm)
Top Facing..............................................16 in. (406 mm)
Side Facing........................................9 3/4 in. (248 mm)
Ceiling...............................................................70 in.(1.8m)
Mantel or Top Facing
Side F
acing
Hearth
Adjacent
Wall
Fig. # 1
26"
660mm
36"
914mm
29 1/2"
749mm
24 1/4"
616mm
10 1/8"
257mm
27 9/16"
700mm
24"
610mm
20 11/16"
526mm
20 11/16"
526mm
3 7/16"
87mm
16 1/16"
408mm
19 1/2"
495mm
19 3/4"
502mm
6 1/4"
159mm
2 7/8"
73mm
Safety
READ ALL INSTRUCTIONS BEFORE INSTALLING
AND USING THIS APPLIANCE. FAILURE TO FOLLOW
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
We strongly recommend that smoke detectors be installed.
If smoke detectors have been previously installed, you may
notice that they are operating more frequently. This may be
due to curing of stove paint or fumes caused by accidentally
leaving the fi re door open. Do not disconnect the detectors.
If necessary, relocate them to reduce their sensitivity.
SAFETY NOTICE: If this stove is not properly installed, a
house fi re may result. For your safety, follow the installation
directions. Consult local building or fi re officials about restric-
tions and installation inspection requirements in your area.
The services of competent installer, certifi ed by the Wood
Energy Technical program (WETT) - in Canada, Hearth Edu-
cation Foundation (HEARTH) - in U.S.A. (or equivalent) are
strongly recommended.