Pacific Energy NEO 2.5 Installation And Operating Instructions Manual - page 16
16 NEO25
110714-24
Optional Blower
The optional blower kit (WODC.BLOW) is equipped with a
three prong power cord and may be installed at any time.
Follow installation instructions supplied with the kit. Route
power supply cord away from heater.
Electrical rating: 115 volts A.C., 60Hz, .5 amps.
Fan output rating: 125 CFM
Blower Operation
Proper blower speed matched with air control setting will
ensure peak performance from your stove. Operate as follows:
- Air control set to "L" (low), operate blower speed control
on "Low".
- Air control set between "L" and "H" (low and high),
operate blower speed control at desired setting.
Automatic: To operate the blower automatically, set the
rocker switch on the side of the fan housing to "Auto" and set
the speed control to desired setting. This will allow the fan to
turn on as the stove heats up to operating temperature. It will
also shut the blower off after the fi re has gone out and the
unit cooled to below a useful heat output range.
Manual: To manually operate the blower, set the rocker switch
to "Man" and set the speed control to desired setting. This will
bypass the sensing device and allow full control of the blower.
Switching from "Auto" to "Man" or selecting speed may be
done anytime.
Optional Outside Air Adaptor
The adaptor(OAIR.1A) is only required if outside combustion
air is being used. Adapter(OAIR.2A) is to be used if you are
ducting in outside air to the rear of the leg adapter and have
a blower unit installed.
Installation(OAIR.1A):
1. Place adaptor over the desired hole in either the bottom or
rear of the leg adapter and secure with #8 x 1/2" screws.
Combustion air duct from outside can now be attached
to the 4" round collar.
Installation(OAIR.2A):
1. Remove blower kit. Place adaptor with the 4" round hole
facing away from the unit and opposite end covering the
room air knockout hole on the back of the leg adapter.
Attach with #8 x 1/2" screws and reinstall fan. Combustion
air duct from outside can now be attached to the 4" round
collar.