Quadra-Fire 5100 ACC Installation Manual - page 12
12
7047-910
October 14, 2013
5100 I-ACC
UL 1777 Insulated Stainless Steel
Liner or Other Approved Lining System
Follow Manufacturer’s Instructions
on Insulation and Support
For Zero or Other Non-Code Clearances,
Follow Approved Liner Manufacturer’s Specific
Insulation Requirements: Different Clearances
May Require Different Specifications
Masonry Chimney Must
Have Structural Integrity
UL 1777 Insulated Stainless Steel
Liner or Other Approved Lining System
Minimum 8 in. (203mm) Masonry
Thickness in Front of Smoke Chamber
Damper Plate Removed or
Fastened in Open Position
Seal with Non-Combustible Material
Minimum Clearance in Accordance
with Insert Listing
Floor Protection in
Accordance with Insert
Listing
Follow Manufacturer’s
Instructions for Maximum
Liner Extension Above
Chimney
Maximum 30
Degrees
Offset in Chimney
Combustible Floor
Masonry Chimney (Cont’d)
This insert conforms with the UL 1482 and ULC S628
(Canada)inallrespects,andisapprovedtoUL&ULCsafety
standardsforinstallationandusewithinafireplacewitha
masonrychimneyinaccordancewithNFPA211andCAN/
CSA-B365-01.
Figure 12.1
NOTE:InCanada,thisfireplaceinsertmustbeinstalled
with a continuous chimney liner of a 6 inch (152mm) diam-
eterextendingfromthefireplaceinserttothetopofthe
chimney.ThechimneylinermustconformtotheClass3
requirementsofCAN/ULC-S635,StandardforLiningSys-
tems for Existing Masonry or Factory-Built Chimneys and
Vents, or CAN/ULC-S640, Standard for Lining Systems
for New Masonry Chimneys.
Generic Insert Model Shown in Illustration