Quadra-Fire 5100 ACC Installation Manual - page 3
October 14, 2013
7047-910
3
5100 I-ACC
Model:
5100-I (ACC) Insert
Laboratory:
Intertek
Report No:
100323198PRT-001a
Type:
SolidFuelType,ListedRoomHeater
Standard:
UL1482 and ULC S628-93 and
(UM)84-HUD,MobileHome
Approved.
TheQuadra-Fire5100WoodInsert(ACC)meetstheU.S.Environ-
mental Protection Agency’s 1990 particulate emission standards.
EPACertified:
4.17 grams per hour
Efficiency:
up to 80.5%
EPA BTU Output:
10,500 to 27,900
Heating Capacity:
2,250 to 3,175 sq ft depend-
ing on climate zone
Vent Size:
6 inches
Firebox Size:
3 cubic feet
Max Wood Length:
22 inches
Max First Hour BTUs:
73,200 @ 75.5% B415
TestedEfficiency
Fuel:
CordWood
Shipping Weight:
480 lbs
1
Important Safety Information
A.InsertCertification
NOTE:Hearth&HomeTechnologies,manufacturerof
this appliance, reserves the right to alter its products, their
specificationsand/orpricewithoutnotice.
C. Mobile Home Approved
• Thisapplianceisapprovedformobilehomeinstalla-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
• Thestructuralintegrityofthemobilehomefloor,ceil-
ing, and walls must be maintained.
• Theappliancemustbeproperlygroundedtotheframe
of the mobile home with #8 copper ground wire, and
chimneymustbelistedtoUL103HToralistedUL-
1777 full length six inch (152mm) diameter liner must
be used.
• Outside Air Kit, part OAK-ACC must be installed in a
mobile home installation.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
Forassistanceoradditionalinformation,consultaqualified
installer, service agency or your dealer.
Quadra-FireisaregisteredtrademarkofHearth&Home
Technologies.
• Installationanduseofanydamagedappliance.
• Modificationoftheappliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installationand/oruseofanycomponentpartnotapprovedby
Hearth&HomeTechnologies.
• Operatingappliancewithoutfullyassemblingallcomponents.
• Operatingappliancewithoutlegsattached(ifsuppliedwithunit).
• DoNOTOverfire-Ifapplianceorchimneyconnectorglows,you
areoverfiring.
Anysuchactionthatmaycauseafirehazard.
WARNING
Fire Risk.
Hearth&HomeTechnologiesdisclaimsany
responsibility for, and the warranty will be voided
by,thefollowingactions:
B.BTU&EfficiencySpecifications
D.GlassSpecifications
Thisstoveisequippedwith5mmceramicglass.Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
Hearth&HomeTechnologiesWILLNOTwarrantystoves
thatexhibitevidenceofover-firing.Evidenceofover-firing
includes,butisnotlimitedto:
• Warpedairtube
• Deterioratedrefractorybrickretainers
• Deterioratedbaffleandotherinteriorcomponents
E. Non-Combustible Materials
Material which will not ignite and burn, composed of any
combinationofthefollowing:
-
Steel
-
Plaster
-
Brick
-
Iron
-Concrete
-Tile
-
Glass
-
Slate
Materials reported as passing
ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace of 750° C.
F. Combustible Materials
Materialmadeof/orsurfacedwithanyofthefollowingma-
terials:
-Wood
-CompressedPaper
- Plant Fibers
- Plastic
-Plywood/OSB
-SheetRock(drywall)
Anymaterialthatcanigniteandburn:flameproofedornot,
plastered or un-plastered.
NOTE:Thisinstallationmustconformwithlocalcodes.Inthe
absence of local codes you must comply with the UL1482, (UM)
84-HUDandNPFA211intheU.S.A.andtheULCS628-93and
CAN/CSA-B365InstallationCodesinCanada.