F. Prefabricated Metal Chimney
Thechimneycanbeneworexisting,masonryorprefabricated
andmustmeetthefollowingminimumrequirements:
•Must be minimum 6 inch (152mm) inside diameter of
hightemperaturechimneylistedtoUL103HT(2100
o
F)
or ULC S628.
•Mustusecomponentsrequiredbythemanufacturerfor
installation.
•Mustmaintainclearancesrequiredbythemanufacturer
for installation.
•Refertomanufacturersinstructionsforinstallation
•Thisinsertis listed to UL 1482 Standard and is approved
for installation into listed factory-built zero clearancefire-
places listed to UL 127 conforming to the following spec-
ificationsandinstructions:
•The original factory-built clearance fireplace chimney
cap must be re-installed after installing the approved
chimney liner meeting type UL 103 HT requirements
(2100°F) per UL 1777.
•IfthechimneyisnotlistedasmeetingHTrequirements,
orifthefactorybuiltfireplacewastestedpriorto1998,a
full height listed chimney liner must be installed from the
appliancefluecollartothechimneytop.
•Thelinermustbesecurelyattachedtotheinsertfluecollar
and the chimney top.
•Theairflowofthefactory-builtzero-clearancefireplace
systemmustnotbealtered.Thefluelinertopsupport
attachmentmustnotreducetheairflowfortheexisting
air-cooled chimney system.
•Nodilutionairisallowedtoenterthechimney.
1.
Securethefireplacedamperintheopenposition.If
this cannot be accomplished, it will be necessary to
remove the damper
2. Seal damper area of chimney around chimney
connector with a high temperature sealant or seal
insertagainstthefaceofthefireplace.
3. Both methods must be removable and replaceable
for cleaning and re-installation.
Minimum 8” (203mm) Masonry Thickness
in Front of Smoke Chamber
Damper Plate Removed or
Fastened in Open Position
Seal with Non-
Combustible Material
Minimum Clearance in Accordance with
Insert Listing
Floor Protection in
Accordance with Insert
Listing
Combustible Floor
Airtight Insulated Clean-Out
Stainless Steel Chimney Connector
Must Extend to Flue Liner
Flue Liner with Required Air Space
E. Metal Heat Circulating Masonry
ThisinsertconformswiththesafetystandardUL-1482and
ULCS628(Canada)inallrespectsandisapprovedtoUL&
ULCsafetystandardsforinstallationandusewithinafire-
place with masonry chimney, in accordance with NFPA 211,
withadirectfluecollarconnection.
Generic Insert Model Shown in Illustration