Quadra-Fire 5100 ACC Installation Manual - page 22
22
7047-910
October 14, 2013
5100 I-ACC
Figure 22.1
Spark Arestor Cap
Roof Flashing
Storm Collar
Joist Shield/Firestop
Double Wall
Connector Pipe
8. Burn wood only. Other types of fuels may generate
poisonous gases (e.g., carbon monoxide).
9. If unit burns poorly while an exhaust blower is on in home,
(i.e., range hood), increase combustion air.
10. Installation shall be in accordance with the Manufacturers
Home&SafetyStandard(HUD)CFR3280,Part24.
NOTICE:
• Offsets from the vertical, not exceeding 45°, are allowed
per Section 905(a) of the Uniform Mechanical Code (UMC).
• Offsets greater than 45° are considered horizontal and are
also allowed, providing the horizontal run does not exceed
75% of the vertical height of the vent.
• Construction, clearance and termination must be in com-
pliancewiththeUMCTable9C.Thisinstallationmustalso
comply with NFPA 211.
NOTICE:Topsectionsofchimneymustberemovabletoallow
maximum clearance of 13.5 feet (411cm) from ground level
for transportation purposes.
1. An outside air inlet must be provided for combustion and
mustremainclearofleaves,debris,iceand/orsnow.It
must be unrestricted while unit is in use to prevent room
air starvation which can cause smoke spillage and an
inabilitytomaintainafire.Smokespillagecanalsoset
off smoke alarms.
2. Unit must be secured to the mobile home structure at
two attachment points. Remove bolts from each side
of insert and use plumbers tape to secure to structure
(a washer may be required). Re-install bolts.
3. Unit must be grounded with #8 solid copper grounding
wire or equivalent and terminated at each end with N.E.C.
approved grounding device.
4. The factory-built fireplace must meet (UM)84-HUD
requirements for outside combustion air supply to
the fireplace fire chamber and the chimney must be
listedtoUL103HToralistedUL-1777fulllengthsix
inch (152mm) diameter liner must be used. It must be
equipped with a spark arrestor cap and the outside air
must be installed on the insert.
5. Refer to
pages 7-8 of this manual for clearance to
combustibles and floor protections requirements.
All
clearances must be followed precisely.
6. Use silicone to create an effective vapor barrier at
the location were the chimney or other component
penetrates to the exterior of the structure.
7. Follow the chimney and chimney connector manufacturer’s
instructionswheninstallingthefluesystemforuseina
mobile home.
CAUTION
THESTRUCTURALINTEGRITYOFTHEMOBILEHOME
FLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINED
DoNOTcutthrough:
• Floorjoist,wall,studsorceilingtrusses.
•
Any supporting material that would affect the structural
integrity.
• NEVERINSTALLINASLEEPINGROOM.
Consumes oxygen in the room.
WARNING
Asphyxiation Risk.
WARNING
Donotdrawoutsidecombustionairfrom:
• Wall,floororceilingcavity
• Enclosedspacesuchasanatticorgarage
• Closeproximitytoexhaustventsorchimneys.
Fumes or odor may result
Fire Risk.
Asphyxiation Risk.
6
Mobile Home Installation