RabbitLink EG2110 User Manual - page 15
User’s Manual
11
3. Configure the RabbitLink network parameters. This is done using the serial console commands.
Typing the command “show” results in a listing of the current network addresses.
Please refer to Appendix E, “Serial Console Commands,” for a description of all the commands.
If a DHCP server was not used , the following serial console commands are required:
set ip x.x.x.x
//
factory default is 10.10.1.100
set gateway x.x.x.x
//
factory default is 10.10.1.1
set netmask x.x.x.x
//
factory default is 255.255.255.0
An alternative for setting the required network addresses is to change the default values in the
RabbitLink firmware,
download.c
.
2.3 Target System Connections to the RabbitLink
After network addresses have been set, put aside the programming cable and connect the program
download cable as shown in Figure 2.3.0-1. One end of the program download cable connects to
the programming header of the Rabbit-based target system. The other end connects to the
PROG
OUT
header of the RabbitLink board.
Figure 2.3.0-1 Connect Rabbit-Based Target System to RabbitLink
Programming Port
Flash
EPROM
Flash
EPROM
SRAM
Colored edge
lines up with
pin 1
Colored edge
Rabbit-Based
Embedded System
Program
Download
Cable
90
15
65
J3
J9
PROG OUT