Sentrol ZX400 Installation Manual

Other manuals for ZX400: Operation Manual, Manual
Manual is about: Control Station

Summary of ZX400

  • Page 1

    1 installation sentrol zx400 /zx410 security system control.

  • Page 2

    2.

  • Page 3: Table of Contents

    3 new features ............................................................................................................. 5 zx400/zx410 wiring diagrams................................................................................ 6 zx400/zx410 terminal descriptions ................................

  • Page 4

    4 specifications and features .................................................................................... 25 control board ........................................................................................................ 25 power supply ..................................................

  • Page 5: New Features

    5 the sentrol zx400/zx410 security control features ease of installation and programming. The zx400/ zx410 is easily programmed with any one of four control stations (lcd, led, ssd, or vfd). The con- trol may also be programmed remotely with the aid of a personal computer (pc) and a modem using sent...

  • Page 6: Zx400/zx410 Wiring Diagrams

    6 see specification and features section for a complete list of compatible accessories. Figure 1 suggested ul household burglar alarm and/or fire (ƒƒ) alarm hookup zx400/zx410 wiring diagrams zx400/zx410 wiring diagrams 3 sw neg green red and black leads red = pos. (+) black = neg. (-) ground screw ...

  • Page 7

    7 figure 2 programmable output and telco supervision wiring diagram zx400/zx410 wiring diagrams +12v neg tg+ tg - com nc no mpi-206 to terminal 10 to terminal 20 optional - when relay is required pg01 programmable output 1 connection +12v neg tg+ tg - com nc no mpi-206 install jumper cut jumper tel ...

  • Page 8

    8 1, 2 ac input connect the appropriate ul class ii transformer using 18 gauge minimum 2 conductor wire. Do not exceed 50 feet. Use a 16.5 vac 35 va transformer or an optional 16.5 vac 20 va transformer. Caution: do not short the terminals of the transformer together. This causes the internal fuse t...

  • Page 9: “2 In 1” Zoning

    9 method 2 wires two separate zone loops back into one set of terminals. The panel recognizes each loop independently because two different eol re- sistor values are used to differentiate between the primary zone (1500 ohm 1/2 watt) and the sec- ondary zone (825 ohm 1/4 watt). This method provides t...

  • Page 10

    10 primary zone and secondary zone infinite ohms 5.24 - 8.25 v open contacts; loop cut or open secondary zone open contact, 1500 ohms 4.24 - 5.23 v primary zone normal primary zone open contact, 825 ohms 3.24 - 4.23 v secondary zone normal primary zone and secondary zone 825 ohms in parallel with 2....

  • Page 11

    11 class ‘b’ end-of-line resistor supervised zones a class ‘b’ zone must be supervised with a 1500 ohm 1/2 watt end-of-line resistor (p/n cr854). This resistor should be installed in series at the furthest point from the control. This configuration must be used whenever both form a and form b device...

  • Page 12

    12 when unsupervised control stations are used, all unsupervised led con- trol stations must be addressed as 1 or 2, all unsupervised ssd control stations must be addressed as 3 or 4, and all unsupervised lcd/vfd con- trol stations must be addressed as 5 or 6. You cannot mix a supervised control sta...

  • Page 13

    13 no control station led’s or display black or red wire removed or cut no response from key presses green wire removed or cut or two supervised control stations at the same address led’s flash and may display “no communication white wire removed or cut from control” code green/white wires reversed ...

  • Page 14: 12 Vdc Outputs

    14 3 sw neg ac xfmr 4 aux12 5 bell 6 2ws 7 neg 8 dat a 9 dat b 10 kp+12 11 neg 12 z1/7 13 z2/8 14 neg 15 z3/9 16 z4/10 17 neg 18 z5/11 19 z6/12 20 neg 1 2 zx400/zx410 j1 j3 outputs 1 2 3 4 5 6 7 8 9 10 neg 12v zxodm d1 d2 12 vdc outputs 12 vdc and additional outputs the zx400/zx410 control provides ...

  • Page 15

    15 outputs may be wired to indicator devices or re- lay module triggers (like the mpi-206) provided the 40 ma current draw condition is not exceeded. Figure 10 shows a wiring example for a relay to odm 1 output 2. Figure 11 shows a wiring ex- ample of odm 1 output 1 to trigger an led. Do not exceed ...

  • Page 16: Expansion Zones

    16 expansion zones zones 13-28 are expansion zones. They may reside on any zone expansion device (zxexp, zem, rf gate- way 1 or rf gateway 2). Assignment of these zones to expansion devices is done through programming (see zx400/zx410 programming manual). The options available for all zones are desc...

  • Page 17: Zxexp Zone Expander Module

    17 this module provides an additional 8 zones for the zx400/zx410 control. If “2 in 1” zoning™ is de- sired, this module provides 16 zones. All zones are fully programmable (see the zx400/zx410 program- ming manual). The zone expander terminals map into zones on the control as shown in table 2. An a...

  • Page 18: Wireless Devices

    18 the zx400/zx410 provides an option for including wireless (or rf) devices.The rf devices may consist of rf zone devices (universals, door contacts, glassbreaks, pirs and smoke detectors) and rf user devices (handhelds). These rf devices require that one or two rf gateways be attached to the syste...

  • Page 19: Fire Zone Modules

    19 fire zone modules fire zone modules zem zone expansion module the zx400/zx410 provides an option for adding class b fire zones. These zones may be connected to zem fire zone expansion modules. There are two models of zems available: 2502-zem two class b zones 2504-zem four class b zones a zem may...

  • Page 20

    20 fire zone modules zone 1 is shown with 2-wire detectors, wired in class b (style b) 2.7k eol 2.7k eol 2.7k eol zone 4 is shown with 2-wire heat detectors and pull stations, wired in class b (style b) heat sensor pull station 2.7k eol -- 429c + + -- + + 429c b+ b- b+ b- b+ b- b+ b- zone 1 zone 2 z...

  • Page 21

    21 fire zone modules note b+ b- b+ b- b+ b- b+ b- zone 1 zone 2 zone 3 zone 4 tb1 power alarm zone 1 trbl alarm zone 2 trbl alarm zone 3 trbl alarm zone 4 trbl relay 1 nc com no nc com no nc com no nc com no relay 2 relay 3 relay 4 zem zrm figure 17 mounting zrm to zem module zrm zone relay module t...

  • Page 22: Power Issues

    22 + - + - battery b battery a to j10 on the zxcfm to bat. - on the control power issues item description standby current per unit (amps) qty total standby current per item (amps) total alarm current per unit (amps) qty total system alarm current (amps) total system standby current (amps) total syst...

  • Page 23

    23 power issues auxiliary power supply installation to increase the available current supplied by the control, a hcp-12sulc power supply may be added. Each hcp-12sulc supplies an additional 450 ma of current, utilizing at least one 12 ah battery. See figure 19. The hcp-12sulc power supply can provid...

  • Page 24

    24 zxptr printer interface module zxptr printer interface module the optional zxptr printer interface module con- nects to the local data bus and can be used for print- ing events in real-time or on command. This mod- ule interfaces with any centronics-style parallel printer. Only one printer may be...

  • Page 25: Specifications and Features

    25 control board • six (6) two-wire zones, each supervised with a 1500 ohm end-of-line resistor. “2 in 1” zon- ing™ provides twelve (12) fully programmable zones with 1500 and 825 ohm resistors. Sys- tem expansion to 28 fully programmable zones via zone expander module, zxexp. • on/off power switch....

  • Page 26

    26 • two pager phone numbers, each can have up to 20 digits • remote programming phone number can have up to 20 digits. • reporting capabilities: two 4-digit account codes per area, two 4-digit system account codes, re- port by zone, opening and closing reports, force arm/bypass reports, restoral re...

  • Page 27

    27 • zxodm: output driver module: provides ten (10) fully programmable 40 ma + 12 vdc out- puts. Nominal current drain: 10 - 13 ma with no outputs connected. • zxptr printer interface module: allows connec- tion of a standard parallel printer via interface. Nominal current drain: 45 - 55 ma without ...

  • Page 28

    28 esl two-wire smoke detectors 429 at, c, ct, crt, cst: standby current: 70 µ a max. (max. 20 detectors per zone) 521 b, bxt, crxt: standby current: 70 µ a max. (max. 20 detectors per zone) 711u, 712u, 713-5u, 713-6u: standby current: 70 µ a max. (max. 20 detectors per zone) 721u, 721ut, 721ud, 722...

  • Page 29: Agency Requirements

    29 agency requirements agency requirements home health care ul 1637 400 4 6 4 n/a ul listed household burglary ul 1023 signaling device household fire csfm 400 24 6 4 required ul listed ul 985 signaling device household burglary/ ul 1023 400 4 6 4 required ul listed fire combination ul 985 24 signal...

  • Page 30

    30 household burglary ul 1023 household fire ul 985 household burglary/household fire combination ul 1023/ul 985 local burglar alarm grades a, b and c central station ul 609 police station connect burglar alarm unit ul 365 digital alarm communicator system ul 1635 home health care signal system ul 1...

  • Page 31

    31 testing this system should be tested weekly. All switches, contacts, and accessories must be ul listed devices. This equipment should be installed in accordance with the national fire protection association stan- dard no. 72 (national fire protection association, batterymarch park, quincy ma 0226...

  • Page 32: System Troubleshooting

    32 system troubleshooting ac failure indicates the loss of ac power or that the ac voltage is not high enough to power the system. Alarm silenced indicates that an auxiliary or holdup alarm condition is present and the alarm has been manually silenced. Bell 1 fault indicates that there is an open in...

  • Page 33: Notes

    33 notes notes ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ _...

  • Page 34: Fcc Compliance

    34 part 68 notification this equipment complies with part 68 of the fed- eral communications commissions (fcc) rules. All connections to the telephone network must be made through standard telephone company plugs and jacks, rj-31x or equivalent, in such a manner as to allow for easy and immediate di...

  • Page 35

    35 limitations the zx400/zx410 is part of a system designed to warn against unauthorized entry or of other situa- tions. However, it is not a guarantee of protection against the occurrence of those events. Any alarm system is subject to compromise or failure to warn for various reasons. Unauthorized...