Sentrol ZX400 Installation Manual - page 26
26
•
Two pager phone numbers, each can have up
to 20 digits
•
Remote programming phone number can have
up to 20 digits.
•
Reporting capabilities: two 4-digit account codes
per area, two 4-digit system account codes, re-
port by zone, opening and closing reports, force
arm/bypass reports, restoral reports, trouble re-
ports, cancel reporting, low battery, AC failure/
restoral.
•
Dual and split reporting capability.
•
Pager capability with 16-digit programmable
message and 2-digit coded messages.
•
Sentrol communication defaults for quick pro-
gramming.
•
Disable call waiting.
Control Stations
•
Color-coded four-wire data bus connection.
•
19-Button Control Station with audible feed-
back.
•
Three (3) Control Station panic button zones.
•
Surface mountable; mounts to any standard
single or double gang electrical box.
•
Built-in piezo sounder.
•
Easy-to-read arming level: AWAY, STAY, and
NIGHT backlit LEDs.
•
Backlit keys with door.
•
Unsupervised Control Stations allows up to 12
Control Stations.
ZXLCD Control Station
•
Backlit display.
•
Two lines x 16 characters LCD display.
•
Area assignable/Multi-area.
•
Addressable with DIP switches, supervised/un-
supervised.
•
Plain English display.
•
Nominal current drain: 20mA - 110mA.
•
Up to six (6) supervised Control Stations per system.
•
Size: 5.33"H x 6.08"W x 1.024"D (135.4 mm x
154.4 mm x 26.0 mm).
•
Optional red plastic for Commercial Fire appli-
cations
SPECIFICATIONS AND FEATURES
ZXVFD Control Station
•
Two lines x 16 characters VFD display.
•
Area assignable/Multi-area.
•
Addressable with DIP switches, supervised/un-
supervised.
•
Plain English display.
•
Nominal current drain: 20 - 170 mA.
•
Up to six (6) supervised Control Stations per system.
•
Size: 5.33"H x 6.08"W x 1.024"D (135.4 mm x
154.4 mm x 26.0 mm).
ZXLED12 Control Station
•
Thirteen (13) LEDs annunciate general purpose
zones 1 through 12 and control board Two-Wire
Fire zone.
•
Ready & trouble LEDs.
•
Addressable as Control Station #1 or #2. Jumper
change makes Control Station unsupervised.
•
Area assignable/Single area.
•
Nominal Current Drain: 23 - 31 mA.
•
Size: 5.0"H x 4.5"W x 1.0"D (127 mm x 114.3
mm x 25.4 mm).
ZXSSD Control Station
•
Three 0.56" (14.2 mm) seven segment display
digits.
•
Ready & trouble LEDs.
•
Up to six (6) supervised Control Stations per system.
•
Area assignable/Multi-area.
•
Addressable with DIP switches, supervised/un-
supervised.
•
Nominal Current Drain: 23 - 116 mA.
•
Size: 5.0"H x 4.5"W x 1.0"D (127 mm x 114.3
mm x 25.4 mm).
Optional Accessories
•
ZXEXP Zone Expander Module: Expands the
control to 8/16 additional zones. Provides an ad-
ditional two-wire smoke zone (max. 10 detec-
tors). Provides 10 additional programmable out-
puts. Nominal current drain: 60 - 72 mA with
no outputs connected.