Sentrol ZX400 Installation Manual - 12 Vdc Outputs
14
3
SW NEG
AC XFMR
4
AUX12
5
BELL
6
2WS
7
NEG
8
DAT A
9
DAT B
10
KP+12
11
NEG
12
Z1/7
13
Z2/8
14
NEG
15
Z3/9
16
Z4/10
17
NEG
18
Z5/11
19
Z6/12
20
NEG
1 2
ZX400/ZX410
J1
J3
OUTPUTS
1 2 3 4 5 6 7 8 9 10 NEG 12V
ZXODM
D1
D2
12 VDC Outputs
12 VDC AND ADDITIONAL OUTPUTS
The ZX400/ZX410 control provides one switched
negative output, one Control Station power output,
one auxiliary power output, one 2-wire smoke power
terminal, one bell output, and one programmable
low current output (PGO1). (See Figure 1).
Additional Outputs
Additional outputs can be added with the ZXODM
Output Driver Modules. Each module receives its
data from the local data bus and provides ten addi-
tional programmable outputs. The outputs provide
+12 VDC on activation and must be limited to 40
mA of current draw. ODM1 has 10 unique outputs.
ODM2 also has 10 unique outputs.
The ODMs may be addressed as ODM1 or ODM2.
You may use multiple ODMs at a given address pro-
vided that power restrictions are followed. The
ODMs come defaulted from the factory as ODM1.
To change from ODM1 to ODM2, remove power,
cut resistor R29, and re-apply power. Connect the
ODMs to the control as shown in Figure 9. Use the
twelve (12) wire cable provided with the ODMs for
the outputs as shown.
Output conditions can be programmed as one of
many conditions. Refer to the ZX400/ZX410 Pro-
gramming Manual for programming information and
restrictions.
A ZXODM may be mounted in the control enclo-
sure using the double-sided tape provided on the
back of the module. For UL Certificated installa-
tions requiring rigid mounting, a ZXODM may be
mounted in a ZX410 control enclosure as shown
in Figure 8 using the stand-offs provided in the
ZEM/ODM Mounting Hardware Pack (P/N
13000515).
Data bus connection
Remove for ODM #2
J3 Connector
RED
Connect to Control terminal 10
GREEN
Connect to Control terminal 8
WHITE
Connect to Control terminal 9
BLACK
Connect to Control terminal 7
D10
C1
1
D5
D4
C10
Q2
D3
ACTIVE
R19
R18
R21
C7
R14
R13
R27
R12
R15
R20
Q1
D2
C6
D1
R16
C4
U2
V3
V2
V1
J2
+
+
D9
D7
D6
R29
R28
C5
R25
R23
R22
R24
R26
C3
J1
J3
ASSEMBLED
IN USA
OUTPUTS
12V A B NEG
1
2
3 4 5 6
7 8
9 10 NEG 12V
R2
R3
R4
R5
R6
R7
R8
R9
R10
R1
1
PC BOARD
MADE IN (USA)
U4
U1
Y1
C2
+
C8
R17
C9
C1
R1
D8
HICKORY, NC
60821484 REV A
COPYRIGHT 1996
SENTROL
CONTROLS GROUP
DATA BUS CONNECTION
1
Tan
13
Burglar
2
Pink
3
Fire
3
Gray
14
Holdup
4
Violet
15
Auxiliary/Medical
5
Yellow
19
Arm AWAY
6
Orange
31
Chime
7
Blue
18
Ready
8
Dk Brown
25
Pre-Alarm
9
Green
34
Lamp
10
White
39
Access
NEG
Black
12V
Red
J3 CONNECTIONS
OUTPUT
WIRE COLOR
DEFAULT
DESCRIPTION
The outputs on this module have lim-
ited transient immunity and should
not leave the enclosure.
Figure 9 ZXODM Wiring Diagram
NOTE
Figure 8 ZXODM Mounting