Sentrol ZX400 Installation Manual - New Features
5
The Sentrol ZX400/ZX410 Security Control features
ease of installation and programming. The ZX400/
ZX410 is easily programmed with any one of four
Control Stations (LCD, LED, SSD, or VFD). The con-
trol may also be programmed remotely with the aid
of a personal computer (PC) and a modem using
Sentrol’s remote programming software (RPM2PRO)
and a panel support module (PRO400). The Control
Stations are easy-to-operate and contain features
such as cross-zoning, delay-before-dialing and an
audibles “mute” function to help reduce false alarms.
The ZX400/ZX410 Security Control is pre-pro-
grammed from the factory with twelve burglar zones
(one delay, two interior, and nine instant) and one
2-wire smoke detector zone to allow for out-of-box
power-up and operation. The twelve burglar zones
have been configured in a ‘paralleled’ condition us-
ing Sentrol’s unique “2 in 1” Zoning™. A zone ex-
pander may be added to provide an additional 2-
wire smoke detector zone and, with the use of “2 in
1” Zoning™, up to 16 additional zones.
Sentrol Series 4000 RF Gateway receivers and sen-
sors allow you to overcome installation obstacles and
increase profit potential. The wireless sensors have
been engineered for long term stability and reliabil-
•
12 Zones with Sentrol’s unique “2 in 1” Zoning™
•
Plus one 2-wire fire zone
•
Expandable to 28 zones, plus two 2-wire fire zones
•
Integrated Sentrol Series 4000 Wireless
•
Two truly independent partitions
•
Up to 50 user codes with 15 levels of authority
•
75 event log
•
Four interchangeable Control Stations to choose from
•
Customized scheduling with special supervisory report
•
Ideal for residential, commercial, and industrial applications
•
Control Station programming in less than 2 minutes with factory defaults
New Features
NEW FEATURES
ity. Using the Series 4000 Wireless System, you can
expand the ZX400/ZX410 to include up to 16 wire-
less zones.
The Control’s on-board RAM maintains its data even
with the power disconnected. A “Watchdog” timer
monitors the microprocessor to ensure the opera-
tional integrity of the system. The ZX400/ZX410
Control Board is equipped with one low current pro-
grammable output (PGO1) and one high current bell
output (BELL) which may be used for Fire, Burglar,
Auxiliary and/or Holdup alarms. In addition, two
ZXODMs (Output Driver Modules) can be added to
provide 20 more programmable low current out-
puts which may be used to trigger other devices.
The ZX400 Security Control may be purchased in
the ZX410 pre-configured package assembly. This
assembly incorporates the ZX400 Control Board
mounted inside a larger 14" x 14" x 3.5" enclosure,
EX1414. The ZX410 must be purchased for Com-
mercial and Industrial UL Listed applications. For UL
Listed Commercial Fire applications, the ZX440F is
available. It consists of the ZX400 Control Board in
a red EX1414 enclosure, with a ZXCFM (Commer-
cial Fire Module), a CR860 dual battery harness and
other cabling.