SVS-Vistek evo1050 Operation Manual - page 18
3 Hardware | 11
3.2 Connectors
3.2.1 LED Blink Codes
NOTICE
To avoid vignetting an optional F-Mount Adapter is
availabe for the evo8050.
NOTICE
Note: Using the available M42-to-C-Mount adapter on
cameras with sensors having a format larger than 1”
may produce vignetting - a darkening of the corners
and edges in the field of view caused by the geometry
of the optics which are used in C-Mount lenses. it is
recommended to use high-quality optical solutions
designed for the M42 x 1mm lens-mounting specification.
Please contact SVS-ViSTEK or your local dealer for a
lens recommendation.
if you must use the M42-to-C-Mount adapter with a
large format sensor, then do not use a lens designed for
less than 1” sensors. Using a lens with a focal length
greater than 50 mm may also help reduce the vignetting
effect.
(Lens solutions for large format CCDs are e.g. available
from SCHNEiDER, QUiOPTiQ, ZEiSS or SiLL.)
“To avoid vignetting, please use
the right lenses”
Blink Codes
LED
Description
yellow slow (1 Hz)
Camera booting
yellow permanent
Camera running
red quick (8 Hz)
Camera is overheating
red slow (1 Hz)
Firmware not configured