SVS-Vistek evo1050 Operation Manual - page 29
4 Software Control | 22
The “Acquisition Control” Folder
“Acquisition Mode”:
Select one of the five
acquisition modes of the camera: None,
Continuous, Software Triggered, Triggered
with internal Exposure Control, Triggered with
External (pulse width driven) Exposure Control
“Trigger Software”:
Will read one image only
if camera is set to “Trigger Software”.
”Trigger Source“:
Select the port of the hard-
ware trigger input.
“CC1”,”CC2”: LVDS input driven from frame
grabber via camera link cable
“Di1”,”Di2”: Single ended inputs on 12pin
Hirose connector (see manual).
”Trigger Polarity“:
Select the polarity of the hardware trigger
input:
“positive” or “negative”
“Acquisition Frame Rate”:
in “continuous” mode (default ex factory) you
can adjust the framerate.
”Exposure time“:
the exposure time can be set
in µsec. The min exposure time is e.g. 20 µsec
(depending on the camera type and speed).
The longest is e.g. 1 second. Due to the
internal timing of the camera the program will
adjust the values to the appropriate value
1
2
1
3
4
5
2
3
4
5
6
6