Tally T6215 Maintenance Manual - page 37
2–11
Chapter 2. Menu Operations
Figure 2–1. Hammer Leadtime Calibration Printout Sample (partial)
Selecting And Running a Platen Gap Calibration Routine
Step 1.
Take the printer offline and place it in Tech Access Mode.
Step 2.
Access the TEST Menu.
Step 3.
Scroll (
▲ Key) until the Diag Category is displayed. Press Enter.
Step 4.
Scroll (
▲ Key) until the Calibrations Parameter is displayed. Press Enter.
Step 5.
Scroll (
▲ Key) until Platen Gap Cal is displayed.
Step 6.
Depress the ENTER key to begin the first part of the Platen Gap Calibration routine.
Step 7.
The message "Set Platen to E and press Enter" displays. Turn the Platen Gap wheel to
the letter E and then press Enter.
Step 8.
The message "Set platen to C and press Enter" displays. Turn the Platen Gap wheel to
the letter C and press Enter.