Chapter 4: Removing and Replacing Components
Procedure 3: Ribbon Motion Sensor PCA Removal
Step 1. Remove the Ribbon Platform (see Procedure 1).
Step 2. Turn the platform over and unplug the orange motor cable(s) and the gray
sensor cable.
Step 3. Remove the two screws that hold the PCA to the platform.
Scre
w
Motor Cab
le
Scre
w
Motor Cab
le
Sensor Cab
le
PCA
Figure 5. Removing PCA screws.
Step 4. Remove the PCA.