Vacon NX User Manual

Manual is about: liquid-cooled drives

Summary of NX

  • Page 1

    ® vacon nx ac drives endat/ssi, sin-cos option board, opt-be sin-cos option board, opt-ak sin-cos with pulse output option board, opt-ar user manual.

  • Page 2

    Index document code: dpd01174 date edited: 01.02.2013 1. Endat/ssi, sin-cos option board opt-be ........................................................................ 3 1.1 opt-be layout and description ..................................................................................................

  • Page 3

    Installation vacon • 3 24- hour service: +358 (0)40 8371 150 • email: vacon@vacon.Com 1 1. Endat/ssi, sin-cos option board opt-be 1.1 opt-be layout and description description: encoder board for vacon nxp with an input for endat/ssi absolute encoder and sin/cos type encoder. Allowed slots: b, c, d, ...

  • Page 4

    4 • vacon installation tel. +358 (0)201 2121 • fax: +358 (0)201 2121 205 1 endat is a bidirectional synchronous serial interface for encoders. For example, the absolute encoder position data can be read and encoder parameters can be set via the endat connection. It also forwards the messages related...

  • Page 5

    Installation vacon • 5 24- hour service: +358 (0)40 8371 150 • email: vacon@vacon.Com 1 1.3 opt-be leds there are two leds on the opt-be board: 1) yellow led (board status led) slow blinking -> board state is ready fast blinking -> board state is faulted 2) green led (encoder led) on -> encoder seri...

  • Page 6

    6 • vacon installation tel. +358 (0)201 2121 • fax: +358 (0)201 2121 205 1 1.5 opt-be parameters number parameter min max default note 7.X.1.1 operating mode 4 8 4 4= endat + sin/cos (default) 5= endat only 6= ssi+sin/cos 7= ssi only 8= sin/cos only note: in modes 5 and 7, only the absolute serial i...

  • Page 7

    Installation vacon • 7 24- hour service: +358 (0)40 8371 150 • email: vacon@vacon.Com 2 2. Sin-cos option board opt-ak 2.1 opt-ak layout and description description: encoder board for vacon nxp with an input for sin/cos type encoder. Programmable control voltage. Allowed slots: c (sin/cos signals ca...

  • Page 8

    8 • vacon installation tel. +358 (0)201 2121 • fax: +358 (0)201 2121 205 1 2 2.2 opt-ak jumper settings note! With +5 v supply voltage, voltage drop with long cabling (about 60 m with 0.5 mm 2 wire section) can become too big for reliable operation. Using +12 v or +15 v encoders is recommended in th...

  • Page 9

    Installation vacon • 9 24- hour service: +358 (0)40 8371 150 • email: vacon@vacon.Com 2 2.4 opt-ak parameters number parameter min max default note 7.3.1.1 pulse/revolution 1 65535 1024 7.3.1.2 invert direction 0 1 0 0 = no 1 = yes 7.3.1.3 reading rate 0 4 1 time used to calculate speed actual value...

  • Page 10

    10 • vacon installation tel. +358 (0)201 2121 • fax: +358 (0)201 2121 205 1 3 3. Sin-cos with pulse output option board opt-ar 3.1 opt-ar layout and description description: encoder board for vacon nxp with an input for sin/cos type encoder. Programmable control voltage for encoder. Differential two...

  • Page 11

    Installation vacon • 11 24- hour service: +358 (0)40 8371 150 • email: vacon@vacon.Com 3 3.2 opt-ar jumper settings note! With +5 v supply voltage, voltage drop with long cabling (about 60 m with 0.5 mm 2 wire section) can become too big for reliable operation. Using +12 v or +15 v encoders is recom...

  • Page 12

    12 • vacon installation tel. +358 (0)201 2121 • fax: +358 (0)201 2121 205 1 3 3.4 i/o terminals on opt-ar, pulse output x3 terminal technical data 1 a+ incremental differential pulse output square wave, signal level rs-422 impedance 120 Ω output current max. 50ma max. Output frequency 200khz output ...

  • Page 13

    Installation vacon • 13 24- hour service: +358 (0)40 8371 150 • email: vacon@vacon.Com 4 4. Installation warning! Internal components and circuit boards are at high potential when the frequency converter is connected to the power source. This voltage is extremely dangerous and may cause death or sev...

  • Page 14

    14 • vacon installation tel. +358 (0)201 2121 • fax: +358 (0)201 2121 205 1 4 c open the cover of the control unit. D install the option board in correct slot on the control board of the frequency converter. Make sure that the grounding plate fits tightly in the clamp. Strip the cable at such distan...

  • Page 16

    Document id: rev. A manual authoring: documentation@vacon.Com vacon plc. Runsorintie 7 65380 vaasa finland subject to change without prior notice © 2013 vacon plc. Find your nearest vacon office on the internet at: www.Vacon.Com.