  • Page 1

    Legend model 937xn model 937xp for use with natural gas for use with propane vented gas fireplace heaters installation and owner’s manual for pedestal base with contemporary front or legs with traditional front please read this manual before installing and operating this heater. This appliance is a ...

  • Page 2: Contents

    2 contents safety information...................................................................................................................................................................................................... 3 1 options................................................................

  • Page 3

    3 safety information due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be ca...

  • Page 4

    4 1 options #710 cfk circulating fan kit (for pedestal base only) is available as an option for this appliance. Operated by a variable speed controller, it is designed to boost the natural convection process through the heater. It may be fitted before the heater is installed or retrofitted at a late...

  • Page 5

    5 with pedestal with legs fig. 1 dimensions & clearances.

  • Page 6

    6 5. Pack contents the complete appliance is contained in two packs. One of the alternative base support and front designs will be included - either pedestal with contemporary fascia or legs with traditional fascia (see pack 2). Pack 1 - main appliance unit contains:- 1 main appliance fitted with wi...

  • Page 7

    7 6.3 fit exhaust port cover (see figure 4) remove four screws from under the top of the firebox. Fit the exhaust port cover and secure with the four screws. 7. Gas supply installation 7.1 route the gas supply line to the appliance inlet connection point (see figure 1). Note: pressure testing the li...

  • Page 8

    8 8. Base & main appliance installation 8.1 pedestal base 8.1.1 detach the pedestal front panel by removing two screws. 8.1.2 place the pedestal in position (see figure 5). The bottom rear of the pedestal must be at least 2½” from the back wall to maintain the 2” rear clearance shown in figure 1. 8....

  • Page 9

    9 8.2.9 replace the door as follows: 8.2.9.1 locate the hinge pin at top of the door into the hole at the top of the door aperture (see figure 8). 8.2.9.2 locate the hinge pin at bottom of the door into the slot in the base. Swing the bottom of the door part way to the back. A new door-retaining bra...

  • Page 10

    10 10. Gas line connection 10.1 open the control panel door. 10.2 pull off the two control knobs. 10.3 detach the control cover panel (see figure 9):- • remove three screws. • lift the panel up • pull the bottom front corner of the panel forward and out to clear the case and then lift clear. 10.4 co...

  • Page 11

    11 12. Ceramic fuel bed assembly 12.1 place the ceramic back wall in position centrally at the back of the firebox. It must rest on the metal ledge at the back of the firebox (see figure 11). 12.2 place the ceramic side walls in position at the sides of the firebox. The sides are left and right hand...

  • Page 12

    12 12.5 place the two front logs in position on the front rail of the firebox. It may be necessary to raise the center log slightly in order to fit the left-hand front log. Make sure that there is a gap of approximately ¼” between the front right stump of the center log and the cut-out section at th...

  • Page 13

    13 14. Aeration adjustment these appliances are equipped with adjustable shutters on both front and rear burner tubes to control primary aeration. The air holes are at the right side of the tubes - see fig 17. The shutters can slide to the right to reduce the air supply or to the left to increase it...

  • Page 14

    14 16. Venting check a check for correct venting of combustion products must be made before the installed appliance is left with the customer. 16. 1 ignite the pilot. Set the main control valve at “max” and the thermostat wheel at “hi”. 16.2 leave for 15 minutes. 16.3 find the draft hood opening at ...

  • Page 15

    15 18. Operating the heater for full lighting instructions see page 17. The operating instructions are also inside the control panel door. 18.1 for your safety this appliance is fitted with a flame supervision device which will shut off the gas supply if, for any reason, the pilot flames go out. Thi...

  • Page 16

    16 21. Checks 21.1 a periodic visual check of the pilot and burner flames should be made (see figures 22 & 23). 21.2 the appliance area must always be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids. 21.3 keep the base of the appliance clear to prevent...

  • Page 17: Lighting Instructions

    17 23. Lighting instructions for your safety read before lighting warning : if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, ...

  • Page 18: Heating