Valor Legend 937XN Installation And Owner's Manual - page 13
13
14.
AERATION ADJUSTMENT
These appliances are equipped with adjustable shutters on both
front and rear burner tubes to control primary aeration.
The air holes are at the right side of the tubes - See fig 17. The
shutters can slide to the right to reduce the air supply or to the left
to increase it.
Your appliance is supplied with the shutters set to suit the vast
majority of installations. No adjustment should usually be
necessary. However, in certain installations (e.g. Low Btu value
gas, high altitude) it may be necessary to adjust the shutter
position of one or both of the burners to obtain the optimal visual
effect.
15.
FASCIA INSTALLATION
15.1
Contemporary front only:
Fit the ashlip to the fascia
unit with 4 screws (see figure 18).
15.2
Locate the fascia unit to the appliance front - see figure
19. Locate at the top corners and at the bottom. We
suggest the following order:
1) Angle the top of the fascia against the upper part of
the appliance front.
2) Push the fascia up between the appliance front and
the appliance top.
3) Push the lower part of the fascia against the appliance
front.
4) Lower the fascia on to the locations.
Fig. 18 Ashlip fixing - Contemporary front
Fig. 19 Facia location (Left side shown)
Rear burner
Front burner
Fig. 17 Aeration shutters