- DL manuals
- Vega
- Radar
- VEGAPULS 63
- Operating Instructions Manual
Vega VEGAPULS 63 Operating Instructions Manual - page 63
VEGAPULS
63
,
low temperature
fl
ange version
201mm (7
29
/
32
")
265mm (10
7
/
16
")
4mm (
5
/
32
")
4mm (
5
/
32
")
ø 44mm
(1
47
/
64
")
ø 75mm
(2
61
/
64
")
4xø
3
/
4
"
4xø
3
/
4
"
8xø
55
/
64
"
8xø
3
/
4
"
8xø
7
/
8
"
4xø
45
/
64
"
8xø
45
/
64
"
8xø
45
/
64
"
4
3
/
4
"
4
59
/
64
"
6
19
/
64
"
5
7
/
16
"
6
7
/
32
"
8
11
/
32
"
35
/
64
"
35
/
64
"
35
/
64
"
3
5
/
8
"
5
/
16
"
4
1
/
64
"
5
/
16
"
5"
6
3
/
16
"
8
1
/
2
"
35
/
64
"
35
/
64
"
35
/
64
"
7
3
/
32
"
9
29
/
64
"
25
/
32
"
25
/
32
"
55
/
64
"
15
/
16
"
3
/
4
"
15
/
16
"
15
/
16
"
6
1
/
2
"
7
7
/
8
"
8
21
/
32
"
11
7
/
32
"
7
1
/
2
"
7
1
/
2
"
9
1
/
2
"
6"
6"
9"
11"
1"
D
mm
b
k
d
x
DN 50 PN 40
165
20
125
4xø18
DN 80 PN 40
200
24
160
8xø18
DN 100 PN 16
220
20
180
8xø18
DN 150 PN 16
285
22
240
8xø22
2" 150 lb
152,4
19,1
120,7
4xø19,1
3" 150 lb
190,5
23,9
152,4
4xø19,1
4" 150 lb
228,6
23,9
190,5
8xø19,1
6" 150 lb
279,4
25,4
241,3
8xø22,4
y
102
8
138
14
158
14
212
14
91,9
8
x
y
127
14
157,2
14
215,9
14
D
inch
b
k
d
DN 50 PN 40
DN 80 PN 40
DN 100 PN 16
DN 150 PN 16
2" 150 lb
3" 150 lb
4" 150 lb
6" 150 lb
d
d
k
D
x
k
D
x
b
y
y
b
2
1
F
ig
.
39
:
VEGAPULS
63
,
low temperature
fl
ange version
1
DN
50
and
2
"
2
DN
80
…
DN
150
and
3
"
…
6
"
d
D
iameter and number of holes in the
fl
ange
S
upplement
VEGAPULS
63
-
4
...
20
m
A
/
HART
63
28436
-
EN
-
070412
Summary of VEGAPULS 63
Page 1
O perating i nstructions vegapuls 63 4 ... 20 m a / hart r adar.
Page 2: Ontents
C ontents 1 a bout this document 1 . 1 f unction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1 . 2 t arget group . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1 . 3 s ymbolism used . . . . . . . . . . . . . . . . . . . . . . . 5 2 f or your safety 2 . 1 a uthorised personnel ...
Page 3
6 . 4 s etup procedure . . . . . . . . . . . . . . . . . . . . . . . 33 6 . 5 m enu schematic . . . . . . . . . . . . . . . . . . . . . . . 40 6 . 6 s aving the parameter adjustment data . . . . . . . 42 7 s etup with pact ware ™ and other adjustment programs 7 . 1 c onnecting the pc . . . . . . . ....
Page 4
S upplementary operating instructions manuals i nformation : vegapuls 63 is available in many versions and is therefore supplied according to customer order . D epending on the selected version , supplementary operating instructions man - uals also come with the delivery . Y ou will fi nd the supple ...
Page 5: Bout This Document
1 a bout this document 1 . 1 f unction t his operating instructions manual has all the information you need for quick setup and safe operation . P lease read this manual before you start setup . 1 . 2 t arget group t his operating instructions manual is directed to trained , quali fi ed personnel . T...
Page 6: Or Your Safety
2 f or your safety 2 . 1 a uthorised personnel a ll operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the operator . F or safety and warranty reasons , any internal work on the instruments must be carried out only by per...
Page 7
L emc : en 61326 : 2004 - e mission : c lass b - s usceptibility : i ndustrial areas l r & tte directive : i - ets 300 - 440 e xpert opinion n o . 0043052 - 02 / see , n oti fi ed b ody n o . 0499 l lvd : en 61010 - 1 : 2002 2 . 6 f ul fi lling namur recommendations w ith regard to interference resist...
Page 8
M odi fi cations not expressly approved by vega will lead to expiry of the operating licence according to fcc / ic . Vegapuls 63 is in conformity with part 15 of the fcc directives and ful fi lls the rss - 210 regulations . N ote the corresponding regulations for operation : l t he instrument must not...
Page 9
L m ount and operate the instrument in such a way that no danger of ignition from electrostatic charges is to be expected . T he antenna , the process fi tting or the housing ( as the case may be depending on instrument version ) are made of electrically non - conductive plastic . L m ake sure that t...
Page 10: Roduct Description
3 p roduct description 3 . 1 c on fi guration t he vegapuls 63 radar sensor is available in two electronics versions : l s tandard electronics type ps 60 kh l e lectronics with increased sensitivity type ps 60 kd t he respective version can be determined by means of the type label on the electronics ...
Page 11
3 2 1 f ig . 1 : vegapuls 63 , fl ange version with plastic housing 1 h ousing cover with integrated plicscom ( optional ) 2 h ousing with electronics 3 p rocess fi tting with encapsulated antenna system 3 . 2 p rinciple of operation vegapuls 63 is a radar sensor in k - band technology ( emitting freq...
Page 12
T he backlight of the indicating and adjustment module is powered by the sensor . T he prerequisite for this is a supply voltage at a certain level . T he exact voltage speci fi cations are stated in chapter " t echnical data " in the " s upplement " . T his function is available for instruments with...
Page 13: Ounting
4 m ounting 4 . 1 g eneral instructions s elect an installation position you can easily reach for mounting and connecting as well as later retro fi tting of an indicating and adjustment module . T he housing can be rotated by 330 ° without the use of any tools . Y ou can also install the indicating a...
Page 14
1 3 2 100% 0% 4 f ig . 3 : m easuring range ( operating range ) and max . Measuring distance 1 full 2 empty ( max . Measuring distance ) 3 m easuring range 4 r eference plane m ake sure that the wetted parts of vegapuls 63 , especially the seal and process fi tting , are suitable for the existing pro...
Page 15
1 2 > 200 mm f ig . 4 : m ounting on round vessel tops 1 r eference plane 2 v essel center or symmetry axis i n vessels with conical bottom it can be advantageous to mount the sensor in the center of the vessel , as measurement is then possible down to the lowest point of the vessel bottom . F ig . ...
Page 16
F ig . 6 : i n fl owing liquid f lush mounting t he optimum installation location of the sensor , also in respect to the cleanability , is fl ush on a block fl ange ( fl ange without socket piece ) or with hygienic fi ttings , e . G . N eumo b iocontrol . M ounting on socket i f the re fl ective propertie...
Page 17
D irect the sensor in liquids as perpendicular as possible to the product surface to achieve optimum measurement results . F ig . 8 : o rientation in liquids t he mounting location of the radar sensor should be a place where no other equipment or fi xtures cross the path of the microwave signals . V ...
Page 18
F ig . 10 : a gitators t hrough the action of fi lling , stirring and other processes in the vessel , dense foams which considerably damp the emitted signals may form on the product surface . I f foams lead to measurement errors , you should use the biggest possible radar antennas and low frequency r...
Page 19
Max. Min. 2 1 f ig . 11 : p ipe antenna system in a tank . T he vent hole in the surge pipe must be in one plane with the polarisation marking on the sensor . 1 m arking of the polarisation direction 2 v ent holde max . ø 5 mm ( 0 . 2 in ) i f possible , the antenna diameter of the sensor should cor...
Page 20
100% 0% 1 > 300 mm f ig . 12 : vegapuls 63 in a bypass tube . T he polarisation marking on the process fi tting must be in one plane to the tube holes or the tube connection openings . 1 m arking of the polarisation direction w hen the sensor is mounted on a bypass tube , the distance from vegapuls 6...
Page 21: Onnecting To Power Supply
5 c onnecting to power supply 5 . 1 p reparing the connection a lways keep in mind the following safety instructions : l c onnect only in the complete absence of line voltage l i f overvoltage surges are expected , overvoltage arresters should be installed t ip : w e recommend using vega overvoltage...
Page 22
C aution : n o grease should be used when screwing the npt cable gland or steel tube into the threaded insert . S tandard grease can contain additives that corrode the connection between threaded insert and housing . T his would in fl uence the stability of the connection and the tightness of the hou...
Page 23
F ig . 13 : c onnection steps 6 and 7 8 p ress down the opening levers of the terminals , you will hear the terminal spring closing 9 c heck the hold of the wires in the terminals by lightly pulling on them 10 c onnect the screen to the internal ground terminal and the external ground terminal to po...
Page 24
1 4 4 4 2 3 f ig . 14 : m aterial versions , single chamber housing 1 p lastic 2 a luminium 3 s tainless steel 4 f ilter element for air pressure compensation of all material versions . B lind stopper with version ip 66 / ip 68 , 1 bar for a luminium and stainless steel i2c display 1 2 5 6 7 8 3 4 1...
Page 25
I2c display 1 1 2 5 6 7 8 f ig . 16 : w iring plan , single chamber housing 1 v oltage supply / s ignal output 5 . 4 w iring plan , double chamber housing t he following illustration apply to non - e x as well as e x ia versions . T he e xd version is described in the next subchapter . 1 2 3 4 5 f i...
Page 26
1 3 2 display 1 2 5 6 7 8 i2c f ig . 18 : e lectronics compartment , double chamber housing 1 p lug connector for vegaconnect ( i ² c interface ) 2 i nternal connection cable to the connection compartment 3 t erminals for vegadis 61 3 1 2 display 1 2 i²c f ig . 19 : c onnection compartment , double ...
Page 27
I2c 1 1 2 f ig . 20 : w iring plan , double chamber housing 1 v oltage supply / s ignal output 5 . 5 w iring plan , double chamber housing e xd 1 2 3 4 5 f ig . 21 : d ouble chamber housing 1 h ousing cover , connection compartment 2 b lind stopper or plug m 12 x 1 for vegadis 61 ( option ) 3 h ousi...
Page 28
1 3 2 display 1 2 5 6 7 8 i2c f ig . 22 : e lectronics compartment , double chamber housing 1 p lug connector for vegaconnect ( i ² c interface ) 2 i nternal connection cable to the connection compartment 3 t erminals for vegadis 61 1 2 1 2 f ig . 23 : c onnection compartment , double chamber housin...
Page 29
1 1 2 f ig . 24 : w iring plan , double chamber housing e xd 1 v oltage supply / s ignal output 5 . 6 w iring plan , version ip 66 / ip 68 , 1 bar + - 1 2 f ig . 25 : w ire assignment , connection cable 1 brown ( + ) and blue (-) to power supply or to the processing system 2 s creen 5 . 7 s witch - ...
Page 30: Adjustment Module
6 s et up with the indicating and adjustment module plicscom 6 . 1 s hort description t he indicating and adjustment module is used for measured value display , adjustment and diagnosis . I t can be mounted in the following housing versions and instruments : l a ll sensors of the plics ® instrument ...
Page 31
R emoval is carried out in reverse order . T he indicating and adjustment module is powered by the sensor , an additional connection is not necessary . F ig . 26 : i nstallation of the indicating and adjustment module n ote : i f you intend to retro fi t vegapuls 63 with an indicating and adjustment ...
Page 32
6 . 3 a djustment system 1.1 2 3 1 f ig . 27 : i ndicating and adjustment elements 1 lc display 2 i ndication of the menu item number 3 a djustment keys l [ ok ] key : - move to the menu overview - con fi rm selected menu - e dit parameter - s ave value l [- > ] key to select : - menu change - list e...
Page 33
6 . 4 s etup procedure i n hart - m ultidrop mode ( several sensors on one input ) the address must be set before continuing with the parameter adjustment . Y ou will fi nd a detailed description in the operating instructions manual " i ndicating and adjustment module " or in the online help of pact ...
Page 34
S tart your parameter adjustment with the following menu items of the basic adjustment : p roceed as follows : 1 m ove from the measured value display to the main menu by pushing [ ok ] . ▶ b asic adjustment d isplay d iagnostics s ervice i nfo 2 s elect the menu item " b asic adjustment " with [- >...
Page 35
E ach product has di ff erent re fl ective properties . I n addition , there are various interfering factors which have to be taken into account : agitated product surfaces and foam generation ( with liquids ); dust generation , material cones and echoes from the vessel wall ( with solids ). T o adapt...
Page 36
Safety " , " s olid " is preset as factory setting . H owever , the instrument should be used preferably in liquids . I n such cases , the vessel form should be set to " s torage tank " during setup . E nter the requested parameter via the appropriate keys , save your settings and jump to the next m...
Page 37
G ating out of false signals c hange now ? P roceed as follows : 1 m ove from the measured value display to the main menu by pushing [ ok ] . 2 s elect the menu item " s ervice " with [- > ] and con fi rm with [ ok ] . N ow the menu item " f alse signal suppression " is displayed . 3 c on fi rm " f al...
Page 38
T he following data are read out or written with this function : l m easured value presentation l a djustment l m edium l i nner diameter of the standpipe ( with standpipe versions ) l v essel form l d amping l l inearisation curve l s ensor - tag l d isplayed value l d isplay unit l s caling l c ur...
Page 39
C urrent output - characteristics 4 … 20 m a c urrent output - max . Current 20 m a c urrent output - min . Current 4 m a c urrent output - failure 3 . 6 m a u nit of measurement m ( d ) t he values of the following functions are not reset to the reset values ( see chart ) with " r eset " : f unctio...
Page 40
6 . 5 m enu schematic i nformation : d epending on the version and application , the light - coloured menu windows are not always available or o ff er nor selection possibility . B asic adjustment 1 ▶ b asic adjustment d isplay d iagnostics s ervice i nfo 1 . 1 m in . Adjustment 0 . 00 % = 10 . 000 m...
Page 41
3 . 1 p ointer d istance min .: 0 . 234 m ( d ) d istance max .: 5 . 385 m ( d ) 3 . 2 m eas . Reliability 8 db s ensor status ok 3 . 3 c urve selection e cho curve 3 . 4 e cho curve p resentation of the echo curve s ervice 4 b asic adjustment d isplay d iagnostics ▶ s ervice i nfo 4 . 1 g ating out...
Page 42
6 . 6 s aving the parameter adjustment data i t is recommended noting the adjusted data , e . G . In this operating instructions manual and archive them afterwards . T hey are hence available for multiple use or service purposes . I f vegapuls 63 is equipped with an indicating and adjust - ment modu...
Page 43: Etup With
7 s etup with pact ware ™ and other adjustment programs 7 . 1 c onnecting the pc ~ = power supply vegaconnect 3 pactware / tm >pa 2 3 1 f ig . 28 : c onnection directly to the sensor 1 rs 232 connection 2 vegapuls 63 3 i ² c adapter cable for vegaconnect 3 n ecessary components : l vegapuls 63 l pc ...
Page 44
2 3 1 4 ~ = power supply vegaconnect 3 pactware / tm f ig . 29 : c onnecting the pc to the signal cable 1 rs 232 connection 2 vegapuls 63 3 hart adapter cable for vegaconnect 3 4 hart resistance 250 o hm n ecessary components : l vegapuls 63 l pc with pact ware ™ and suitable vega dtm l vegaconnect ...
Page 45
N ote : k eep in mind that for setup of vegapuls 63 , dtm - c ollection in the actual version must be used . A ll currently available vega dtm s are provided in the dtm c ollection on cd and can be obtained from the responsible vega agency for a token fee . T his cd includes also the up - to - date ...
Page 46: fi
8 m aintenance and fault recti fi cation 8 . 1 m aintenance w hen used as directed in normal operation , vegapuls 63 is completely maintenance free . 8 . 2 r emove interferences vegapuls 63 o ff ers maximum reliability . N evertheless faults can occur during operation . T hese may be caused by the fol...
Page 47
? 4 … 20 m a signal missing l w rong connection à c heck connection according to chapter " c onnection steps " and if necessary , correct according to chapter " w iring plan " l n o voltage supply à c heck cables for breaks ; repair if necessary l supply voltage too low or load resistance too high à...
Page 48
8 . 3 e xchange of the electronics module i f the electronics module is defective , it can be replaced by the user . I n e x applications , only an instrument and an electronics module with appropriate e x approval may be used . I f there is no electronics module available on site , one can be order...
Page 49
L ps - e . 60 kd d ( d = approvals kx , kf according to vega product list ) l ps - e . 60 kd e ( e = approvals cx , dx , ck , ci , dm , xm , cm , di , ex , gi , gx , ux , uf according to vega product list ) 8 . 4 i nstrument repair i f a repair is necessary , please proceed as follows : y ou can dow...
Page 50: Ismounting
9 d ismounting 9 . 1 d ismounting steps w arning : b efore dismounting , be aware of dangerous process con - ditions such as e . G . Pressure in the vessel , high temperatures , corrosive or toxic products etc . T ake note of chapters " m ounting " and " c onnecting to power supply " and carry out t...
Page 51: Upplement
10 s upplement 10 . 1 t echnical data g eneral data m aterials , wetted parts - p rocess fi tting 316 l - a ntenna encapsulated or hygieni - cally encapsulated ptfe ( tfm 1600 ), pfa plated , pvdf - p rocess seal with hygienically en - capsulated antenna v iton , epdm m aterials , non - wetted parts ...
Page 52
Min . Distance from fl ange 50 mm ( 1 . 969 in ) meas . Range depending on process fi tting - t ri - c lamp 2 " , 3 " up to 10 m ( 32 . 808 ft ) - bolting dn 50 , dn 80 up to 10 m ( 32 . 808 ft ) - fl ange dn 50 , ansi 2 " up to 10 m ( 32 . 808 ft ) - f lange dn 80 … dn 150 , t ri - c lamp 4 " , ansi 3...
Page 53
R eceived average emitted power reaching an object directly in front of the antenna - d istance 1 m ( 3 . 28 ft ) 108 n w per cm ² ( 108 - 9 w / cm ² ) or 108 n w per 0 . 155 in 2 ( 108 x 10 - 9 w / 0 . 155 in 2 ) - d istance 5 m ( 16 . 404 ft ) 4 . 3 n w per cm ² ( 4 . 3 - 9 w / cm ² ) or 4 . 3 n w...
Page 54
1,0 m 20 m 30 mm 15 mm -15 mm -30 mm f ig . 32 : a ccuracy vegapuls 63 with increased sensitivity in mm , measuring range in m 3.280 ft 65.62 ft 1.180 in 0.590 in - 0.590 in - 1.180 in f ig . 33 : a ccuracy vegapuls 63 with increased sensitivity in i nch , measuring range in ft i n fl uence of the am...
Page 55
G as phase t emperature 1 bar / 14 . 5 psi 10 bar / 145 psi 50 bar / 725 psi h ydrogen 20 ° c / 68 ° f - 0 . 01 % 0 . 10 % 0 . 61 % h ydrogen 200 ° c / 392 ° f - 0 . 02 % 0 . 05 % 0 . 37 % w ater ( saturated steam ) 100 ° c / 212 ° f 0 . 20 % - - w ater ( saturated steam ) 180 ° c / 356 ° f - 2 . 1 ...
Page 56
E lectromechanical data - version ip 66 / ip 67 and ip 66 / ip 68 ; 0 . 2 bar c able entry / plug 12 ) - s ingle chamber housing l 1 x cable entry m 20 x 1 . 5 ( cable - ø 5 … 9 mm ), 1 x blind stopper m 20 x 1 . 5 or : l 1 x cloasing cap m 20 x 1 . 5 , 1 x blind stopper m 20 x 1 . 5 or : l 1 x clos...
Page 57
- m ax . Length 1000 m ( 3280 ft ) - m in . Bending radius 25 mm ( 1 in ) at 25 ° c ( 77 ° f ) - d iameter approx . 8 mm ( 0 . 315 in ) - c olour - standard pe b lack - c olour - standard pur b lue - c olour - e x - version b lue i ndicating and adjustment module p ower supply and data transmission ...
Page 58
1000 750 500 250 14 18 16 20 22 24 26 28 30 32 34 36 Ω v 4 1 2 3 f ig . 34 : v oltage diagram 1 hart load 2 v oltage limit ee x ia instrument 3 v oltage limit non - e x / e x instrument 4 s upply voltage v oltage supply - v ersion with increased sensitivity s upply voltage - n on - e x instrument 15...
Page 59
1000 750 500 250 15 18 16 20 22 24 26 28 30 32 34 36 Ω v 4 1 2 3 f ig . 35 : v oltage diagram for version with increased sensitivity 1 hart load 2 v oltage limit ee x ia instrument 3 v oltage limit non - e x / e x instrument 4 s upply voltage e lectrical protective measures p rotection - p lastic ho...
Page 60
Atex d atex ii 1 / 2 g , 2 g ee x d ia iic t 6 atex d + d atex ii 1 / 2 g , 2 g ee xd ia iic t 5 + atex ii 1 / 2 d ip 6 x t iec ia iec e x ia iic t 6 iece x iec e x td a 20 / 21 ip 66 t , a 21 fm fm ci . I , d iv 2 ( ni ) + ci . Ii , iii , d iv 1 ( dip ); fm ci . I - iii , d iv 1 ( is ); fm ci . I -...
Page 61
10 . 2 d imensions h ousing in protection ip 66 / ip 67 and ip 66 / ip 68 ; 0 . 2 bar 112mm (4 13 / 32 ") 117mm (4 39 / 64 ") 116mm (4 9 / 16 ") 120mm (4 23 / 32 ") ~ 69mm (2 23 / 32 ") ø 77mm (3 1 / 32 ") ~ 69mm (2 23 / 32 ") ~ 116mm (4 9 / 16 ") ~ 87mm (3 27 / 64 ") ø 77mm (3 1 / 32 ") ø 84mm (3 5...
Page 62
Vegapuls 63 , fl ange version 100mm (3 15 / 16 ") 163mm (6 27 / 64 ") 4mm ( 5 / 32 ") 4mm ( 5 / 32 ") ø 44mm (1 47 / 64 ") ø 75mm (2 61 / 64 ") 4xø 3 / 4 " 4xø 3 / 4 " 8xø 55 / 64 " 8xø 3 / 4 " 8xø 7 / 8 " 4xø 45 / 64 " 8xø 45 / 64 " 8xø 45 / 64 " 4 3 / 4 " 4 59 / 64 " 6 19 / 64 " 5 7 / 16 " 6 7 / 32...
Page 63
Vegapuls 63 , low temperature fl ange version 201mm (7 29 / 32 ") 265mm (10 7 / 16 ") 4mm ( 5 / 32 ") 4mm ( 5 / 32 ") ø 44mm (1 47 / 64 ") ø 75mm (2 61 / 64 ") 4xø 3 / 4 " 4xø 3 / 4 " 8xø 55 / 64 " 8xø 3 / 4 " 8xø 7 / 8 " 4xø 45 / 64 " 8xø 45 / 64 " 8xø 45 / 64 " 4 3 / 4 " 4 59 / 64 " 6 19 / 64 " 5 7...
Page 64
Vegapuls 63 , hygienic fi tting 1 1 2 3 4 60mm (2 23 / 64 ") 46mm (1 13 / 16 ") ø 90mm (3 35 / 64 ") ø 66mm (2 19 / 32 ") 85mm (3 11 / 32 ") 20mm ( 25 / 32 ") ø 78mm (3 5 / 64 ") 60mm (2 23 / 64 ") 46mm (1 13 / 16 ") ø 50mm (1 31 / 32 ") ø 90mm (3 35 / 64 ") 100mm (3 15 / 16 ") f ig . 40 : vegapuls 6...
Page 65
Vegapuls 63 , hygienic fi tting 2 1 2 7mm ( 9 / 32 ") w w 99mm (3 57 / 64 ") 163mm (6 27 / 64 ") 12mm ( 15 / 32 ") dn 50 2” iso2852 dn 50 / 2” w clamp-stutzen clamp-socket din32676/ dn 50 / 2,5” dn 65 / 3” dn 80 / 3,5” dn 100 / 4” ø 64 ø 77,5 ø 91 ø 106 ø 119 dn 80 3,5” ≥ ≥ ≥ ≥ f ig . 41 : vegapuls 6...
Page 66
Vegapuls 63 , hygienic fi tting 3 1 2 3 4 8mm ( 5 / 16 ") ø 92mm (3 5 / 8 ") ø 124mm (4 7 / 8 ") 100mm (3 15 / 16 ") 163mm (6 27 / 64 ") 14mm ( 35 / 64 ") 8mm ( 5 / 16 ") ø 94mm (3 45 / 64 ") ø 133mm (5 15 / 64 ") 100mm (3 15 / 16 ") 163mm (6 27 / 64 ") 14mm ( 35 / 64 ") f ig . 42 : vegapuls 63 , hyg...
Page 67
Vegapuls 63 , hygienic fi tting 4 1 2 8mm ( 5 / 16 ") ø 84mm (3 5 / 16 ") ø 114mm (4 31 / 64 ") 100mm (3 15 / 16 ") 163mm (6 27 / 64 ") 14mm ( 35 / 64 ") f ig . 43 : vegapuls 63 , hygienic fi tting 4 1 sms dn 51 2 sms dn 76 s upplement vegapuls 63 - 4 ... 20 m a / hart 67 28436 - en - 070412.
Page 68
10 . 3 i ndustrial property rights vega product lines are global protected by industrial property rights. Further information see http://www.Vega.Com . Only in u.S.A.: further information see patent label at the sensor housing. Vega produktfamilien sind weltweit gesch ü tzt durch gewerbliche schutzr...
Page 69
S upplement vegapuls 63 - 4 ... 20 m a / hart 69 28436 - en - 070412.
Page 70
S upplement 70 vegapuls 63 - 4 ... 20 m a / hart 28436 - en - 070412.
Page 71
S upplement vegapuls 63 - 4 ... 20 m a / hart 71 28436 - en - 070412.
Page 72
Vega g rieshaber kg a m h ohenstein 113 77761 s chiltach g ermany p hone + 49 7836 50 - 0 f ax + 49 7836 50 - 201 e - mail : info @ de . Vega . Com www . Vega . Com iso 9001 a ll statements concerning scope of delivery , application , practical use and operating conditions of the sensors and process...