Waldorf BP8080G Installation And Operation Manual - page 13
11
Installation
Clearances
The following minimum installation clearances are to be adhered to:
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
Assembly
NOTE:
This appliance must only be installed on adjustable feet supplied. It must not be
fitted with rear rollers or castors as this appliance is intended for stationary
installations only.
Appliance must be positioned securely and level. This should be carried out on
completion of gas connection. Refer to ‘Gas Connection’ section.
Optional Accessories (Refer to Replacement Parts List)
Rear Roller Kit. For installation details, refer to instructions supplied with each kit.
Plinth Kit. For installation details, refer to instructions supplied with each kit.
1.
Check that all feet are in place and are tightened firmly.
2.
Roughly adjust feet to make bratt pan steady and level.
3.
To assemble handle to lid, unpack handle assembly. Place handle on
outside of lid with curved part of handle facing downwards. (Refer to
Fig 1).
4.
Fit bolts with spring washers and flat washers from inside of lid and
tighten bolts to secure handle in position.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN
AUTHORISED PERSON.
1.
It is essential that gas supply is correct for appliance to be installed
and that adequate supply pressure and volume are available. The
following checks should be made before installation:-
a. Gas Type appliance has been supplied for is shown on
coloured stickers located above gas connection and on rating
plate. Check that this is correct for gas supply, appliance is
being installed for. Gas conversion procedure is shown in this
manual.
b. Supply Pressure required for this appliance is shown in
'Specifications' section of this manual. Check gas supply to
ensure adequate supply pressure exists.
c. Input Rate of this appliance is shown on Rating Plate and in
'Specifications' Section of this manual. Input rate should be checked against available gas supply
line capacity. Particular note should be taken if appliance is being added to an existing
installation.
NOTE: It is important that adequately sized piping runs directly to connection joint on
appliance with as few tees and elbows as possible to give maximum supply volume.
2.
Fit gas regulator supplied, into gas supply line as close to appliance as possible.
3.
NOTE: Gas pressure regulator provided with this appliance is convertible between Natural Gas
and LPG as per ‘Gas Conversion Section’ in this manual.
Ensure regulator is converted to correct gas type that appliance will operate on.
Regulator outlet pressure is fixed ex-factory for gas type that regulator is converted to
and it is NOT to be adjusted.
Handle
Nut
Spring & Flat
Washers
Fig 1
Lid
Rating Plate
Location
Fig 2
Combustible Surface
Non Combustible Surface
Left / Right hand side
50mm
0mm
Rear
50mm
0mm