Waldorf BP8080G Installation And Operation Manual - page 28
26
Gas Conversion and Specifications
Gas Specifications
- Australia:
- New Zealand:
- UK Only:
Category:
II
2H3P.
Flue Type: A
1.
NOTE:
* - Measure burner operating pressure at gas control outlet test point with burner
operating at ‘High’ setting. Operating pressure is ex-factory set through appliance
regulator and is not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas
LP Gas (Propane)
BP8080G / GE
BP8120G / GE
BP8080G / GE
BP8120G / GE
Main Burner Injector
Ø 4.30mm
Ø 5.20mm
Ø 2.50mm
Ø 2.80mm
Pilot Burner Injector
0.35
Aeration Clearance (H)
30mm 30mm
Operating Pressure
0.76kPa (*)
0.60kPa (*)
2.4kPa (*)
2.5kPa (*)
Gas Regulator Cap Screw
0.20
Natural Gas (G20)
LP Gas (Propane) (G31)
BP8080G / GE
BP8120G / GE
BP8080G / GE
BP8120G / GE
Main Burner Injector
Ø 4.30mm
Ø 5.20mm
Ø 2.50mm
Ø 2.80mm
Pilot Burner Injector
0.35 0.20
Aeration Clearance (H)
30mm 30mm
Supply Pressure
20mbar 37mbar
Burner Operating Pressure
7.5mbar (*)
6.0mbar (*)
25.7mbar (*)
25.5mbar (*)
Gas Regulator Cap Screw
Natural Gas
LP Gas
BP8080G / GE
BP8120G / GE
BP8080G / GE
BP8120G / GE
Main Burner Injector
Ø 4.30mm
Ø 5.20mm
Ø 2.50mm
Ø 2.80mm
Pilot Burner Injector
0.35
Aeration Clearance (H)
30mm 30mm
Burner Operating Pressure
0.76kPa (*)
0.60kPa (*)
2.4kPa (*)
2.5kPa (*)
Gas Regulator Cap Screw
0.20