Waldorf BP8080G Installation And Operation Manual - page 29
27
Gas Conversion and Specifications
- All Other Markets:
(*) NOTE:
* - Measure burner operating pressure at gas control outlet test point with burner
operating at ‘High’ setting. Operating pressure is ex-factory set through appliance
regulator and is not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas
LPG
Butane
BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE BP8080G / GE BP8120G / GE
Main Burner
Ø 4.30mm
Ø 5.20mm
Ø 2.50mm
Ø 2.80mm
Ø 2.40mm
Ø 2.60mm
Pilot Burner
0.35 0.20 0.20
Aeration Clearance
30mm 30mm 30mm
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure
0.76 kPa (*)
0.60 kPa (*)
2.4 kPa (*)
2.5 kPa (*)
2.4 kPa (*)
2.5 kPa (*)
Gas Regulator Cap Screw
2.75 - 4.50 kPa