WarmingTends DMLS60-3V LP Instruction Manual - 11) Warranty
15
Below are some potential causes and countermeasures to the symptoms
indicated in bold. Please contact your retailer or certified
technician for service & repair.
No Pilot Flame (Hot Wire Glows)
1. Air in gas line. If new install, may take several attempts to purge air
2. Debris in gas line. Confirm gas line is clear (insulation, dirt, plastic etc..)
3. Gas Pressure Improper Confirm proper gas pressure (Section 1)
4. Pilot Orifice Dirty Remove pilot head and clean (Section 8)
No Main Burner (Pilot Lights)
1. Gas Pressure Improper Confirm proper gas pressure (Section 1)
2. Small Pilot Flame Remove pilot head and clean orifice. ( Section 8)
3. Dirty Thermocouple Clean using soft brush (Section 8)
4. Crossfire Burner Obstructed Confirm no debris or water in burner (Always
cover Fireplace!)
5. Improperly applied Media See (Section 5)
Main Burner Turning Off/On Frequently
1. Small Pilot Flame Remove pilot head and clean orifice (Section 8)
2. Improperly applied Media See (Section 5)
3. Gas Pressure Improper Gas pressure too low (Section 1)
4. Thermocouple Defective Change Thermocouple.
Noise
1. Whistling Sound Change Flex line routing
11) Warranty
Limited Warranty
Warming Trends warranties Fireplaces against manufacturing defects that
prevent safe and correct function as follows:
• Electronics, Gas Valve, & Pilot Assembly: Commercial-6mos;
Residential- 1 yr.
• Aluminum plate, Brass Crossfire Burner: LIFETIME
This commences from the date of original sale / shipment from Warming
Trends FOB Littleton, Colorado. This warranty is for parts and in-house
(Warming Trends) labor. The defective product must be sent back to
Warming Trends with a Return Merchandise Authorization (RMA) issued by
Warming Trends for that specific product and any other additional
information for the nature of the defect or warranty claim.
The warranty does not cover items that have been damaged by overheating,
modification, abuse, flooding or improper storage. Also any labor involving
installation or maintenance with the unit is not covered.
This warranty excludes claims for consequential, indirect-collateral expenses
arising from product defects or warranty recovery.