WarmingTends DMLS60-3V LP Instruction Manual - 2) Location
4
2) Location
Warning: For electronic ignition models there must be an electrical
shut off ( wall switch or breaker ) on the exterior of the Fireplace or on
adjacent wall to allow for emergency shutdown and maintenance.
Warning: All Fireplaces must have a gas shutoff on the outside of
the exterior of the Fireplace to allow for emergency shut off and
maintenance.
Warning: Select a location where the Fireplace can be attended
during operation. Never leave an operating Fireplace unattended or by
someone not familiar with its operation or emergency shut off locations.
Warning: Both children and adults should be alerted to the hazards
of high surface temperatures and should stay away to avoid burns and
clothing ignition.
Warning: Young children should be carefully supervised when they
are in the area of Fireplace.
Warning: Clothing or other flammable materials should not be
placed on or near Fireplace.
Warning: Fireplaces create very high temperatures - Combustibles
must be located far enough away that there is no risk of ignition.
IMPORTANT: It is recommended that material such as granite, marble
or other dense stone be kept away from 6-10” from flame due to risk of
cracking. Manufacturer is not responsible for damage.
Fireplace Clearances – See Figures 1 and 2 On Last Pages
• Under Valve Box When Applicable 2”
• Sides Surrounding Fireplace 36” From Structure or
Combustibles
• Overhead Clearance 120” Over Head
• Choose a location that allows easy access for installation and
maintenance of the Fireplace.
• Pick a location that allows sufficient horizontal room to enjoy the
Fireplace while allowing a safe distance from the heat and flame .
3) Construction of the Enclosure
Warning: For electronic ignition models there must be an electrical
shut off ( wall switch or breaker ) on the exterior of the Fireplace or on
adjacent wall to allow for emergency shutdown and maintenance. Verify
correct 110VAC or 24VAC Supply.
Warning: All Fireplaces must have a gas shutoff on the outside of
the exterior of the Fireplace to allow for emergency shut off and
maintenance.
Warning: Always use proper materials and construction for gas
supply, power and enclosure.
Warning: The enclosure using LP gas must incorporate 1 vent on at