WarmingTends DMLS60-3V LP Instruction Manual - page 6
6
installer to test for gas leaks at all connections.
Warning: When filling the pan with lava rock and/or decorative
glass, the instructions in Section 5 must be followed.
Warning: Gas Plumbing Connections: Use only joint compound or
tape that is resistant to all gases. Apply joint compound to all male pipe
fittings only- DO NOT use on FLARED fittings. Be sure to tighten every
joint securely.
Warning: For systems with an extended or detached valve box the
area in which the valve box is installed must conform with all installation
requirements to include but not limited to location, construction, venting
and local codes. Failure to do so may result inpersonal injury property
damage or explosion.
WARRANTY REQUIREMENT: Warranty is void if valve box is opened
• Purge gas lines of air.
• Perform all leak test with leak detector or leak reactant.
• Verify correct gas type and pressure.
• Perform leak test on main gas supply. Repair leaks as necessary.
• Shut Off Gas Supply and Power to fireplace.
• Connect fire-pit to main gas supply. If using flex line avoid sharp
bends with flex line to prevent whistling.
• Turn on gas supply and perform leak test on all inlet connections.
Repair as needed.
• For electronic ignition models hook up proper 110VAC or 24VAC
electrical power following all local codes.
• On electronic ignition models The 6’ power cord can be either tied
into the main power supply for use with wall switch or plugged
into remote receiver to use remotely.
• Position Fireplace safely with access to all gas connections for
testing.
• Light Fireplace. It may take several cycles to purge air from the
lines.
o For electronic ignition models apply proper 110VAC or 24
VAC.
• Once Fireplace is lit perform leak test on all gas connections.
Repair as needed.
• Turn off Fireplace and allow to cool.
• Apply media as described in (Section 5).
• Turn on Fireplace again and perform leak test with media correctly
installed. If gas leak is detected verify correct media application
and repair as needed.
• Set Fireplace in properly constructed enclosure (Section 3).
• Verify correct operation and lighting.
• Review safety manual with end user and instruct not to change/
modify Fireplace or media.
• Leave manual with end user.
IMPORTANT: On electronic ignition models please apply the Start Up
and Shutdown decal next to control switch in an obvious position.