WarmingTends DMLS60-3V LP Instruction Manual - 5) Media
7
5) Media
Warning: FOR GLASS MEDIA USAGE WITH LP GAS- WHEN
USING APPROVED DECORATIVE GLASS TO COVER BURNER APPLY
ONLY ENOUGH TO HIDE BURNER. APPLYING OVER 1/2” MAY
CREATE BACK PRESSURE AND GAS LEAKAGE FROM AIR MIXER
RESULTING IN LP POOLING UNDER FIREPLACE.
Warning: FOR GLASS MEDIA USAGE WITH LP GAS- THE UNIT
MUST BE TESTED WITH MEDIA OVER BURNER FOR
CONFIRMATION OF NO BACK PRESSURE CREATING GAS TO LEAK
OUT OF AIR MIXER VENTURI HOLES. THIS MAY HAVE TO BE DONE
PRIOR TO PLACING IN ENCLOSURE IF NO ACCESS DOOR.
Warning: The Fireplace is designed to use approved media correctly
installed over the burner to achieve proper combustion.
WARRANTY REQUIREMENT: Never install a mesh or screen under the
media.
IMPORTANT: Media affects flame pattern greatly. It is possible to
create an unusual flame pattern that could damage your enclosure.
Enclosure damage from an open flame fire feature is not covered under
any warranty.
Lava Rock & Glass Application
Please follow the instructions below to add the finishing touch to your
Fireplace. Remember the deeper your lava rock or glass the more risk of
reducing if not smothering the flame. Particular attention needs to be on
the pilot assembly area. Incorrect media installation will cause the pilot
flame to suffocate and turn off pit or delay main burner ignition.
Lava Rock Only Application
1) Install your Fireplace per instructions.
2) Apply lava rock ONLY deep enough to cover burner and pan less than
1” below crossfire burner jets.