WarmingTends DMLS60-3V LP Instruction Manual - page 3
3
The steps listed as:
Warnings: Contains information critical to the safe installation and
operation of the fire-pit.
WARRANTY REQUIREMENT: Must be strictly followed to qualify for
product warranty.
Warranty will be void if not followed.
IMPORTANT: Are notes and insights to help ensure product satisfaction
and serviceability.
---------------------------------------------------------------------------------
Warning: It is the installer’s responsibility to ensure a safe
installation and to educate the end user as to proper
operation. Leave this manual with the end user.
Warning: Never alter product or configuration in any way.
Warning: FOR REMOTE CONTROL USE: To prevent accidental start-
up from unwanted RF signals it is the responsibility of the end user to
turn off power to electric outlet for the remote control receiver when the
fire-pit is not in use via wall switch or breaker.
Warning: We suggest that our products be installed by professionals
that are locally licensed by the authority having jurisdiction in gas piping.
We suggest that our products be serviced annually by a professional
certified in the US by the National Fireplace Institute (NFI) as NFI Gas
Specialists or in Canada by WETT (Wood Energy Technical Training).
Installer must follow all instructions carefully to ensure proper
performance and safety. Warming Trends Company is not responsible for
your actions.
Warning: Product is not intended to be a starter for wood or any
other combustibles.
Warning: It is the responsibility of the installer to follow ALL LOCAL
CODES concerning the installation and operation of the Fireplace. In the
absence of local codes, please follow:
● Fixed piping system: The National Fuel Gas Code, ANSI
Z223.1/NFPA 54 or International Fuel Gas Code.
● Electrical ground: The National Electrical Code, ANSI/NFPA 70.
Warning: Only use gas/fuel type specified for this Fireplace see label
on the Fireplace control Box. Verify correct
gas/fuel type and pressure. Never use an alternative fuel to include bio-
fuel, ethanol, lighter fluid or any other fuel.
Gas pressure and type should be checked prior to use and
installation.
● Natural Gas Fireplace:
Supply Pressure: Minimum: 3.5” W.C.; Maximum: 5.0” W.C.
Outlet Pressure: 3.5” W.C.
● LP Gas:
Supply Pressure: Minimum: 10.0” W.C.; Maximum: 11.0” W.C.
Outlet Pressure: 10.0” W.C