To install the circulating pump
GBW 300
46
9.3.
Aquavent 6000 S circulating pump
NOTE:
When you integrate the circulating pump, ensure that the delivery rate
only falls under 2500 l/h temporarily. Permanent operation at less than
2500 l/h will result in the impeller thrust washer suffering wear.
Fig. 20: Aquavent 6000 S circulating pump
Installation position
Fig. 22: Delivery rate and flow resistance
Aquavent 6000 S circulating pump
* Clamping area of the stand clamp
min. 5°
Delivery rate
(with water at 20 °C)
Flow resistance
(with the pump stopped)
Fig. 21: Hole pattern for the stand for the Aquavent 6000 S
circulating pump