Weber Motor MPE 850 Service Manual - page 61
61
SHB MPE850 Rev 1.2 | 408014 | 408090 | 408101 |
10
9
7
8
6
5
11
The ignition coils must not be replaced always.
(See chapter 4.1 Service intervals.)
►
Replace the ignition coils
6
.
►
Insert the ignition coils.
►
Replace the serrated lock washers
7
.
Assemble the bolts
8
, washers
9
and
serrated lock washers as illustrated.
Tightening torque:
8 Nm +2 Nm [5.9 lbf ft +1.5 lbf ft]
►
Connect the wire harness connectors to the
ignition coils
10
.
►
Touch up the paintwork defects.
►
Clear the service counter to reset service
light. (See the Weber Diagnostic Tool
manual.)
►
Update the engine control unit calibration.
(See the Weber Diagnostic Tool manual.)
8 Service tasks in the workshop
8.6 Replacing spark plugs and igition coils
►
Unscrew the spark plugs
5
using a spark
plug wrench.
►
Replace the spark plugs.
►
Screw in the spark plugs using a spark plug
wrench.
Tightening torque:
22 Nm +10 Nm [16.2 lbf ft +7.4 lbf ft]
►
Place the engine cover
11
and press down
the engine cover until it is snapped.
►
Test-drive the vehicle.