WEG CFW-11 Installation Manual - page 16
Installation Guide
16 | CFW-11
EN
GL
IS
H
Table 2: Conducted and radiated emission levels for sizes A to D
Inverter
model (with
built-in RFI
filter)
Without external
RFI filter
With external RFI filter
Cond
uc
te
d
em
is
si
o
n -
m
ax
im
um
m
o
to
r
ca
b
le
le
ng
th
R
ad
iat
ed
em
is
sio
n
External
RFI filter
part number
(manufacturer:
EPCOS)
Cond
uc
te
d
em
is
si
o
n -
m
ax
im
um
m
o
to
r
ca
b
le
le
ng
th
R
ad
iat
ed
em
is
si
o
n -
ca
te
go
ry
C
at
eg
o
ry
C3
C
at
eg
o
ry
C2
C
ate
g
o
ry
(n
o m
et
alli
c
cab
in
et
re
q
ui
re
d)
C
at
eg
o
ry
C2
C
at
eg
o
ry
C1
W
ith
ou
t met
al
lic
ca
bi
net
In
si
de
a
m
et
al
lic
ca
bi
net
CFW11 0006
S 2 O FA
100 m
(328.10 ft)
7 m
(23.00 ft)
C2
B84142-
A16-R122
75 m
(246.06 ft)
50 m
(164.04 ft)
C2
C2
B84142-B16-R
100 m
100 m
(328.10 ft)
CFW11 0007
T 2 O FA
100 m
(328.10 ft)
5 m
(16.40 ft)
C2
B84143-
G8-R110
100 m
(328.10 ft)
-
C2
C2
B84143-
A8-R105
50 m
(164.04 ft)
50 m
(164.04 ft)
CFW11 0007
S 2 O FA
100 m
(328.10 ft)
7 m
(23.00 ft)
C2
B84142-
A16-R122
75 m
(246.06 ft)
50 m
(164.04 ft)
C2
C2
B84142-B16-R
100 m
(328.10 ft)
100 m
(328.10 ft)
CFW11 0010
S 2 O FA
100 m
(328.10 ft)
7 m
(23.00 ft)
C2
B84142-
A30-R122
75 m
(246.06 ft)
50 m
(164.04 ft)
C2
C2
B84142-B25-R
100 m
(328.10 ft)
100 m
(328.10 ft)
CFW11 0010
T 2 O FA
100 m
(328.10 ft)
5 m
(16.40 ft)
C2
B84143-
G20-R110
100 m
(328.10 ft)
-
C2
C2
B84143-
A16-R105
50 m
(164.04 ft)
50 m
(164.04 ft)
CFW11 0013
T 2 O FA
100 m
(328.10 ft)
5 m
(16.40 ft)
C2
B84143-
G20-R110
100 m
(328.10 ft)
-
C2
C2
B84143-
A16-R105
50 m
(164.04 ft)
50 m
(164.04 ft)
CFW11 0016
T 2 O FA
100 m
(328.10 ft)
5 m
(16.40 ft)
C2
B84143-
G20-R110
100 m
(328.10 ft)
-
C2
C2
B84143-
A25-R105
50 m
(164.04 ft)
50 m
(164.04 ft)
CFW11 0024
T 2 O FA
100 m
(328.10 ft)
No
C2
B84143-
A36-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C2
C2
CFW11 0028
T 2 O FA
100 m
(328.10 ft)
No
C2
B84143-
A36-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C2
C2
CFW11 0033
T 2 O FA
100 m
(328.10 ft)
No
C2
B84143-
A50-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C2
C2
CFW11 0045
T 2 O FA
100 m
(328.10 ft)
No
C3
B84143-
A50-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
CFW11 0054
T 2 O FA
100 m
(328.10 ft)
No
C3
B84143-
A66-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
CFW11 0070
T 2 O FA
100 m
(328.10 ft)
No
C3
B84143-
A90-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
CFW11 0086
T 2 O FA
100 m
(328.10 ft)
No
C3
B84143-
A120-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
CFW11 0105
T 2 O FA
100 m
(328.10 ft)
No
C3
B84143-
A120-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
CFW11 0003
T 4 O FA
100 m
(328.10 ft)
5 m
(16.40 ft)
C2
B84143-
G8-R110
100 m
(328.10 ft)
-
C2
C2
B84143-
A8-R105
50 m
(164.04 ft)
50 m
(164.04 ft)
CFW11 0005
T 4 O FA
100 m
(328.10 ft)
5 m
(16.40 ft)
C2
B84143-
G8-R110
100 m
(328.10 ft)
-
C2
C2
B84143-
A8-R105
50 m
(164.04 ft)
50 m
(164.04 ft)
CFW11 0007
T 4 O FA
100 m
(328.10 ft)
5 m
(16.40 ft)
C2
B84143-
G8-R110
100 m
(328.10 ft)
-
C2
C2
B84143-
A8-R105
50 m
(164.04 ft)
50 m
(164.04 ft)
CFW11 0010
T 4 O FA
100 m
(328.10 ft)
5 m
(16.40 ft)
C2
B84143-
G20-R110
100 m
(328.10 ft)
-
C2
C2
B84143-
A16-R105
50 m
(164.04 ft)
50 m
(164.04 ft)
CFW11 0013
T 4 O FA
100 m
(328.10 ft)
5 m
(16.40 ft)
C2
B84143-
G20-R110
100 m
(328.10 ft)
-
C2
C2
B84143-
A16-R105
50 m
(164.04 ft)
50 m
(164.04 ft)
CFW11 0017
T 4 O FA
100 m
(328.10 ft)
No
C2
B84143-
A25-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C2
C2
CFW11 0024
T 4 O FA
100 m
(328.10 ft)
No
C2
B84143-
A36-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C2
C2
CFW11 0031
T 4 O FA
100 m
(328.10 ft)
No
C2
B84143-
A36-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C2
C2
CFW11 0038
T 4 O FA
100 m
(328.10 ft)
No
C3
B84143-
A50-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
CFW11 0045
T 4 O FA
100 m
(328.10 ft)
No
C3
B84143-
A50-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
CFW11 0058
T 4 O FA
100 m
(328.10 ft)
No
C3
B84143-
A66-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
CFW11 0070
T 4 O FA
100 m
(328.10 ft)
No
C3
B84143-
A90-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
CFW11 0088
T 4 O FA
100 m
(328.10 ft)
No
C3
B84143-
A120-R105
100 m
(328.10 ft)
100 m
(328.10 ft)
C3
C2
Table 3: Conducted and radiated emission levels for sizes E to G
Inverter model
(built-in RFI
filter)
Fr
am
e
Without external
RFI filter
With external RFI filter
Conducted
emission -
maximum
motor
cable length
Radiated
emission
External RFI
filter part number -
(manufacturer: EPCOS)
Conducted
emission -
maximum motor
cable length
Radiated
emission
- without
metallic
cabinet
Category C3 Category
Category C2
Category
CFW11 0142 T2
E
100 m (328.10 ft)
C2
B84143-B0150-S020
100 m (328.10 ft)
C2
CFW11 0180 T2
100 m (328.10 ft)
C2
B84143-B0180-S020
(1)
100 m (328.10 ft)
C2
CFW11 0211 T2
100 m (328.10 ft)
C2
B84143-B0250-S020
(2)
100 m (328.10 ft)
C2
CFW11 0105 T4
100 m (328.10 ft)
C2
B84143-B0150-S020
100 m (328.10 ft)
C2
CFW11 0142 T4
100 m (328.10 ft)
C2
B84143-B0150-S020
100 m (328.10 ft)
C2
CFW11 0180 T4
100 m (328.10 ft)
C2
B84143-B0180-S020
(1)
100 m (328.10 ft)
C2
CFW11 0211 T4
100 m (328.10 ft)
C2
B84143-B0250-S020
(2)
100 m (328.10 ft)
C2
CFW11 0242 T4
F
100 m (328.10 ft)
C3
(3)
B84143-B0250-S021 100 m (328.10 ft)
(4)
C3
CFW11 0312 T4
100 m (328.10 ft)
C3
(3)
B84143-B01420-S021 100 m (328.10 ft)
(4)
C3
CFW11 0370 T4
100 m (328.10 ft)
C3
(3)
B84143-B0400-S021 100 m (328.10 ft)
(4)
C3
CFW11 0477 T4
100 m (328.10 ft)
C3
(3)
B84143-B0600-S021 100 m (328.10 ft)
(4)
C3
CFW11 0515 T4
G
100 m (328.10 ft)
C3
(3)
B84143-B0600-S021 100 m (328.10 ft)
(4)
C3
CFW11 0601 T4
100 m (328.10 ft)
C3
(3)
B84143-B0600-S021 100 m (328.10 ft)
(4)
C3
CFW11 0720 T4
100 m (328.10 ft)
C3
(3)
B84143-B1000-S021 100 m (328.10 ft)
(4)
C3
Notes for table 3:
(1) For inverter/filter surrounding air temperature higher than 40 °C (104 °F) and continuous
output current higher than 172 Arms, it's required to use B84143B0250S020 filter.
(2) For inverter/filter surrounding air temperature of 40 °C (104 °F) and HD applications (heavy
duty cycle, output current
(3) With a toroidal core in the three mains cable. Example: TDK PN: PC40 UU120x160x20.
(4) 2.5 Hz minimum operating frequency.
INTEGRAL KEYPAD - HMI-CFW11
Left “Soft key”: Function
defined by the text
directly above on the
display.
1. Increases the
parameter contents.
2. Increases the speed.
3. Selects the previous
group of the Parameter
Group list.
Controls the motor
speed direction.
Active when:
P0223=2 or 3 in LOC
and /or
P0226=2 or 3 in REM.
Selects between LOCAL
or REMOTE situation.
Active when:
P0220=2 or 3.
It accelerates the motor following the acceleration ramp up to the speed defined in P0122.
It keeps the motor at this speed as long as pressed.
When released it decelerates the motor following the deceleration ramp down to stop.
Active when all the conditions below are fulfilled:
1. Run/Stop=Stop;
2. General Enable=Active;
3. P0225=1 in LOC and/or P0228=1 in REM.
Decelerates the motor
following the deceleration
ramp, down to stop.
Active when:
P0224=0 in LOC and/or
P0227=0 in REM.
Accelerates the
motor following the
acceleration ramp.
Active when:
P0224=0 in LOC and/or
P0227=0 in REM.
1. Decreases the
parameter contents.
2. Decreases the speed.
3. Selects the next group
of the Parameter
Group list.
Right “Soft key”:
Function defined by the
text directly above on the
display.
Figure 26: Keypad keys and functions