Table A.3: Dynamic braking specifications for sizes A to E
Inverter model
Maximum braking
current
(I
max
)
[A]
Maximum braking
power (peak value)
(P
max
)
(2)
[kW]
Effective braking
current
(I
effective
)
(1)
[A]
Dissipated power
(mean value) in the
braking resistor
(P
R
)
(2)
[kW]
Recommended
resistor
[Ω]
Power wire size (terminals
DC+ and BR)
[mm
2
(AWG)]
CFW11 0006 B 2
5.3
2.1
5.2
2.03
75
1.5 (16)
CFW11 0006 S 2 O FA
5.3
2.1
5.2
2.03
75
1.5 (16)
CFW11 0007 B 2
7.1
2.9
6.96
2.71
56
1.5 (16)
CFW11 0007 S 2 O FA
7.1
2.9
6.96
2.71
56
1.5 (16)
CFW11 0007 T 2
5.3
2.1
5.2
2.03
75
1.5 (16)
CFW11 0010 S 2
11.1
4.4
10.83
4.22
36
2.5 (14)
CFW11 0010 T 2
7.1
2.9
6.96
2.71
56
1.5 (16)
CFW11 0013 T 2
11.1
4.4
8.54
2.62
36
2.5 (14)
CFW11 0016 T 2
14.8
5.9
14.44
5.63
27
4 (12)
CFW11 0024 T 2
26.7
10.7
19.15
5.5
15
6 (10)
CFW11 0028 T 2
26.7
10.7
18.21
4.97
15
6 (10)
CFW11 0033 T 2
26.7
10.7
16.71
4.19
15
6 (10)
CFW11 0045 T 2
44
17.6
33.29
10.1
9.1
10 (8)
CFW11 0054 T 2
48.8
19.5
32.17
8.49
8.2
10 (8)
CFW11 0070 T 2
48.8
19.5
26.13
5.6
8.2
6 (8)
CFW11 0086 T 2
93
37.2
90.67
35.3
4.3
35 (2)
CFW11 0105 T 2
111.1
44.4
90.87
29.7
3.6
35 (2)
CFW11 0003 T 4
3.6
2.9
3.54
2.76
220
1.5 (16)
CFW11 0005 T 4
5.3
4.3
5.2
4.05
150
1.5 (16)
CFW11 0007 T 4
5.3
4.3
5.2
4.05
150
1.5 (16)
CFW11 0010 T 4
8.8
7
8.57
6.68
91
2.5 (14)
CFW11 0013 T 4
10.7
8.5
10.4
8.11
75
2.5 (14)
CFW11 0017 T 4
12.9
10.3
12.58
9.81
62
2.5 (12)
CFW11 0024 T 4
17
13.6
16.59
12.9
47
4 (10)
CFW11 0031 T 4
26.7
21.3
20.49
12.6
30
6 (10)
CFW11 0038 T 4
36.4
29.1
26.06
14.9
22
6 (8)
CFW11 0045 T 4
47.1
37.6
40
27.2
17
10 (8)
CFW11 0058 T 4
53.3
42.7
31.71
15.1
15
10 (8)
CFW11 0070 T 4
66.7
53.3
42.87
22.1
12
10 (6)
CFW11 0088 T 4
87.9
70.3
63.08
36.2
9.1
25 (4)
CFW11 0142 T 2 O DB
266.7
106.7
142
30.2
1.5
70 (2/0) or 2x 25 (2x 4)
CFW11 0180 T 2 O DB
266.7
106.7
180
48.6
1.5
120 (4/0) or 2x 35 (2x 2)
CFW11 0211 T 2 O DB
333.3
133.3
211
53.4
1.2
150 (300) or 2x 50 (2x 1)
CFW11 0105 T 4 O DB
186
148.8
105
47.4
4.3
50 (1)
CFW11 0142 T 4 O DB
266.7
213.3
142
60.5
3
70 (2/0) or 2x 25 (2x 4)
CFW11 0180 T 4 O DB
266.7
213.3
180
97.2
3
120 (4/0) or 2x 35 (2x 2)
CFW11 0211 T 4 O DB
363.6
290.9
191.7
80.8
2.2
120 (250) or 2x 50 (2x 1)
Notes:
(1) The effective braking current presented is just an indicative value, because it depends on the braking duty cycle. The effective braking current can be obtained from the equation below, where t
br
is given in minutes and corresponds to the sum of all braking times during the most severe cycle of 5 (five) minutes.
I
effective
= I
max
· t
br
5
√
(2) The P
max
and P
R
values (maximum and mean power of the braking resistor respectively) presented are valid for the recommended resistors and for the effective braking currents presented in the
table. The resistor power must be changed according to the braking duty cycle.