WoodPro WS-TS-1500 Owner's Manual - page 5
LOCATING THE STOVE
Page 5
WoodPRO™
1.
The stove must be placed on solid concrete, solid
masonry, or when installed on a combustible
ƀQQr,
on an Underwriters Laboratories Listed Type 2
ƀoor
protector listed to UL standard UL 1618, such as
Hy-C or Imperial Model UL4056BK. Floor protector
must be 1/2
Ŋ/13mm minimum thickness (R value
= 1.19, K value = 0.84 see page 23 for calculation
formulas) non-combustible material or equivalent.
The
ƀQQT protector must extend at least ŊEO
beyond the front of the access door,
ŊEO to
the sides, 8
Ŋ21cm beyond the rear and must
extend under and
ŊOO beyond either side of
the stove pipe if it is elbowed towards a wall. (See
ſIWTGU 4 – 6 and consult local building codes and
ſTGRTQVGEVKQPQTFKPCPEGs.)
CAUTION: FIRE HAZARD. CARPETING AND
OTHER COMBUSTIBLE MATERIAL SHALL
NOT COVER THE FLOOR PROTECTOR. THESE
MATERIALS MUST REMAIN OUTSIDE OF COM-
BUSTIBLE CLEARANCES, SEE FIG. 4 – 6
2.
The room in which the stove is installed must have
a minim
WOƀQQTVQEGKNKPIJGKIJVQHHV. (2.13 m).
3.
The stove must have its own
ƀue. Do not con-
nect this unit to a chimney flue serving other
appliances. DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.
4.
After observing the clearances to combus-
tible materials (
ſgures 4 – 6), locate your ƀoor
protector accordingly (figure 4) and careful-
ly place the stove in your selected location.
Install connector pipe, elbows, and th
s
a
e
l
b
m
i
required, utilizing either a recently cleaned and
inspected
ŊOO lined masonry chimney or a
6
Ŋ152mm i.d. manufactured chimney system listed
VQ7.*6 757.%5 %#0
5.
Use round 6
Ŋ152mm dia., minimum 24 MSG black
or 26 MSG blue steel stove pipe to connect the
stove to the chimney. Do not use galvanized stove
pipe. NOTE: Mobile home installations require
double-wall UL 103 HT high-temp connector
pipe. Secure connector pipe to the
ƀWG collar with
three (3) equally spaced sheet metal screws to
ſrmly hold the pipe sections together. DO 0OT
%100'%6 THIS STO8' TO #0; AIR DISTRIBU-
6+1014&7%65;56'/
6.
Recheck clearances from the stove, con -
n e c t o r s t ove p i p e, a n d c o r n e r c l e a ra n c -
es using the illustrations in figures 4 – 6 and
your local building codes or fire protection
ordinances.
NOTE: ANY WALL CONTAINING COMBUSTI
-
BLE MATERIAL SUCH ASWOODEN STUDS OR
DRYWALL AND FACEDWITH BRICK OR STONE
MUST BE CONSIDERED A COMBUSTIBLE
SURFACE.
NOTICE: for installation in a manufactured/
mobile home (USA only), please see
URGEKſE
requirements on page 13.
8.
T h e c l e a ra n c e s p r ov i d e d a r e m i n i mu m
dimensions set by US standard UL 1482-2011 &
7.%5 tested and applied by Polytests
Services, Inc. the manufacturer’s testing
agency.
Clearances listed and shown MUST be adhered to
for safe operation of this appliance. CLEARANCES
MAY NOT BE REDUCED BY ANY MEANS IN USA
OR CANADA.
. This stove meets U.S. Test Standard: UL 1482-
2011& Canadian Standard:
7.%5
CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FROM THE
STOVE.
NOTE: BEFORE FIRING WOODSTOVE SLIDE
FIREBRICKS TOWARDS THE REAR SO NO
GAPS REMAIN BETWEEN BRICKS.