Feature and Option List
It is recommended to configure all the features and options listed below using the configuration tool found on the module
flashing page on www.directechs.com. The web offers more options; however, manual configuration of the features is possible
using the information on this page.
* Default option
Feat.
Operation
Flashes / Option
Description
1. No RF Output*
Module is connected to a remote starter using a standard installation.
2. RFTD Output
Module is connected to an XL202 using an RSR or RXT installation (when
available).
3. SmartStart
Module is connected to SmartStart using an RSR or RXT installation (when
available).
1. Driver priority*
Unlocks only the driver door on first press and unlocks all doors on a
second press within 5 seconds.
2. All
Unlocks all doors on first press.
1. Disabled*
No operation.
2. Enabled
When the feature is enabled, it will activate the Heated Seats and heated
steering wheel.
1. Disabled*
No operation.
2. Enabled
When the feature is enabled, it will activate the rear defroster and heated
mirrors.
1. 32° Farenheit (0°
Celsius)*
When Heated Seats or Defroster feature is enabled, it will activate the
feature upon remote start when temperature is below 32 °F (0 °C).
2. 23° Farenheit (-5°
Celsius)
When Heated Seats or Defroster feature is enabled, it will activate the
feature upon remote start when temperature is below 23 °F (-5 °C).
3. 41° Farenheit (5°
Celsius)
When Heated Seats or Defroster feature is enabled, it will activate the
feature upon remote start when temperature is below 41 °F (5 °C).
4. Always ON
When Heated Seats or Defroster feature is enabled, it will activate the
feature at any temperature.
1. High*
When Heated Seats are activated, they will be set to HIGH.
2. Low
When Heated Seats are activated, they will be set to LOW.
1. Disabled
The OEM alarm will not be controlled by DBALL upon remote start. No
disarm or arm command will be executed at the beginning or end of the
sequence; it must be controlled by the Remote Starter.
2. Safelock
Smart OEM Alarm Control will behave like a standard Safelock feature on a
remote starter. It will unlock at the beginning of the sequence, and relock
after start and shutdown.
3. Enabled*
Smart OEM Alarm Control will synchronize with the OEM alarm so that it
will disarm and rearm the vehicle in the remote start sequence, only when
required. The reason for this is, factory alarm control must often be done by
lock or unlock operation. This could create unnecessary actions on door
lock modules, such as the horn to honk. When possible, Smart OEM Alarm
Control will monitor the alarm and door lock status to detect if the disarm or
rearm is required. If the vehicle is unlocked or is not equipped with factory
alarm, the disarm/rearm will not be executed. Smart OEM Alarm Control will
also monitor the remote starter actions so that the factory alarm control is
not done twice. A remote starter, for which the Safelock feature is active,
will work perfectly with this option and will make it invisible to the user.
1
RFTD Output Type
2
Unlock Driver Priority
3
Heated Seats
7
Smart OEM Alarm Control
4
Defroster
5
Heated Seats/Defroster
Temperature Control
6
Heated Seats Temperature
Level
LED
Status
Description
Troubleshooting
Off
Module has no power.
Check the power connections.
Solid red
Start of programming is normal
If the LED is red after the ignition is ON, check for CAN-High
and CAN-Low connections as the ignition is not seen on
CAN.
Flashes green fast
Normal. CAN programmed and waiting for
bypass programming.
Normal operation
Flashes orange
slowly
Normal. Waiting for offline key2go
programming.
Solid green for 3
seconds with a quick
orange flash.
Module successfully programmed or is
already programmed.
Normal operation
Solid green for 3
seconds.
Module successfully programmed.
Normal operation
Module programming - Error codes
Flashes red x2
CAN not detected.
Check the Tan - Tan/Black wire connections. Wake up the
data bus by turning the ignition on and try again.
Flashes red x3
Bypass data not detected.
Check the bypass line connection, make sure there is a
continuity between the 2 sides of the cut and turn the ignition
ON. Make sure the battery was removed when turning the
ignition ON.
External Module Synchronisation
Flashes red, red,
then orange x 10
OBDII feature not supported.
Diagnostic data bus not detected. Some features are not
supported by SmartStart. This can be caused by missing
wire connections or module hardware limitation. Refer to
the wiring installation section to check the connections.
Active Ground While Running
Flashes green
GROUND OUT ON (GWR) command
received.
Otherwise, the Ground While Running (status) signal
was lost or was never received by the module.
Commands can come from RF, D2D or W2W.
Flashes red &
orange
IGNITION ON command received.
Otherwise, the ignition signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
Flashes green
quickly
START ON command received.
Otherwise, the start signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
D2D and W2W Commands
Flashes orange x 1
LOCK command received.
Flashes orange x 2
UNLOCK command received.
Flashes orange x 3
TRUNK command received.
Module programming - Firmware specific
Commands can come from RF, D2D or W2W.
Solid
OFF
Flashes
Flashes
Solid and
quick flash
Solid
Flashes
red x2
Flashes
red x3
Flashes
red, red,
orange x10
Flashes
green
Flashes
green
Flashes
orange x1
Flashes
orange x1
Flashes
orange x1
Flashes
orange x1
Flashes
orange x2
Flashes
orange x3
Flashes red
& orange