Xpresskit DBALL Installation Manual - page 7
Rev.: 20160610
Platform: DBALL/DBALL2
Firmware:
CHRYSLER7
© 2016 Directed. All rights reserved.
Page 7
1
Solid
Wait until the LED turns ON solid red.
Remove the battery from the factory keyless remote
&
Open
and
remove
battery
PA
NIC
x2
x2
PA
NIC
x2
x2
6
Disconnect the module and complete the Key2GO programming.
2
Use the tip of the remote to press on the Start/Stop button (PTS) twice
to turn the ignition ON ("RUN" illuminates on Start/Stop switch).
The LED flashes green.
&
Flashes
to ON
(RUN)
ENGINE
START
STOP
PUSH x2
PA
NIC
x2
x2
Refer to the LED Diagnostics section on page 12 for more information and for troubleshooting purposes.
Go to the next page to complete the module programming.
3
Press on the Start/Stop button (PTS) once to turn the ignition OFF.
to OFF
ENGINE
START
STOP
PUSH x1
&
Flashes
5
Press on the Start/Stop button (PTS) once to turn the ignition OFF.
to OFF
ENGINE
START
STOP
PUSH x1
to ON
(RUN)
ENGINE
START
STOP
PUSH x2
PA
NIC
x2
x2
4
Press on the Start/Stop button (PTS) twice
to turn the ignition ON. The LED flashes orange slowly.
&
Flashes
Slowly
Important
Make all the required connections to the vehicle, as described in the wiring diagram(s) found in this guide, and double check to
ensure everything is correct prior to moving onto the next step.
Warning!
To take advantage of advanced features, you must use XpressVIP 4.5 (and higher) or the Directechs Mobile app.
When the flashing operation is successful, you can proceed with the programming instructions below.
OR
If required for your installation, connect the 10-pin, 12-pin and 14-pin harnesses to
the module, then connect the 4-pin D2D harness.
D2D Installation
W2W Installation
If required for your installation, connect the 10-pin and 12-pin harnesses to the
module, then connect the 14-pin harness to the module.
10-pin
D2D
st
1
12-pin
14-pin
nd
2
rd
3
10-pin
D2D
st
1
th
4
12-pin
14-pin
nd
2
rd
3
Flashing a module using your computer:
1. Connect the interface module to your computer using the
XKLoader2.
2. Go to www.directechs.com using Internet Explorer, and
select the Flash Module button.
3. Follow the instructions to select your vehicle, installation
type, and configure your options.
4. Once you have configured the firmware options, click on the
FLASH button.
Flashing a module using your smartphone or tablet
1. Connect the interface module to your XKLoader3.
2. Launch the Directechs Mobile app on your smartphone or
tablet.
3. Select FLASH YOUR MODULE and follow the on screen
instructions.
Module Programming
LED
Status
Description
Troubleshooting
Off
Module has no power.
Check the power connections.
Solid red
Start of programming is normal
If the LED is red after the ignition is ON, check for CAN-High
and CAN-Low connections as the ignition is not seen on
CAN.
Flashes green fast
Normal. CAN programmed and waiting for
bypass programming.
Normal operation
Flashes orange
slowly
Normal. Waiting for offline key2go
programming.
Solid green for 3
seconds with a quick
orange flash.
Module successfully programmed or is
already programmed.
Normal operation
Solid green for 3
seconds.
Module successfully programmed.
Normal operation
Module programming - Error codes
Flashes red x2
CAN not detected.
Check the Tan - Tan/Black wire connections. Wake up the
data bus by turning the ignition on and try again.
Flashes red x3
Bypass data not detected.
Check the bypass line connection, make sure there is a
continuity between the 2 sides of the cut and turn the ignition
ON. Make sure the battery was removed when turning the
ignition ON.
External Module Synchronisation
Flashes red, red,
then orange x 10
OBDII feature not supported.
Diagnostic data bus not detected. Some features are not
supported by SmartStart. This can be caused by missing
wire connections or module hardware limitation. Refer to
the wiring installation section to check the connections.
Active Ground While Running
Flashes green
GROUND OUT ON (GWR) command
received.
Otherwise, the Ground While Running (status) signal
was lost or was never received by the module.
Commands can come from RF, D2D or W2W.
Flashes red &
orange
IGNITION ON command received.
Otherwise, the ignition signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
Flashes green
quickly
START ON command received.
Otherwise, the start signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
D2D and W2W Commands
Flashes orange x 1
LOCK command received.
Flashes orange x 2
UNLOCK command received.
Flashes orange x 3
TRUNK command received.
Module programming - Firmware specific
Commands can come from RF, D2D or W2W.
Solid
OFF
Flashes
Flashes
Solid and
quick flash
Solid
Flashes
red x2
Flashes
red x3
Flashes
red, red,
orange x10
Flashes
green
Flashes
green
Flashes
orange x1
Flashes
orange x1
Flashes
orange x1
Flashes
orange x1
Flashes
orange x2
Flashes
orange x3
Flashes red
& orange