Xpresskit DBALL Installation Manual - page 12
Rev.: 20160610
Platform: DBALL/DBALL2
Firmware:
CHRYSLER7
© 2016 Directed. All rights reserved.
Page 12
LED Diagnostics & Troubleshooting
LED
Description
Troubleshooting
Module has no power.
Make sure the D2D harness is connected or that the 12
Volt is present between the red and black wires. If the
12 Volt is present, the module may be defective.
Waiting to begin the programming sequence.
Ensure the correct programming procedure is being
followed.
CAN programmed and waiting for bypass programming.
Normal operation.
Waiting for offline Key2GO programming.
Normal operation.
Module successfully programmed or is already
programmed.
Normal operation.
Module successfully programmed
Normal operation
CAN not detected.
Check the Tan - Tan/Black wire connections. Wake up
the data bus by turning the ignition on and try again.
Bypass data not detected.
Check the bypass line connection, make sure there is a
continuity between the 2 sides of the cut and turn the
ignition ON. Make sure the battery was removed when
turning the ignition ON.
OBDII feature not supported.
Diagnostic data bus not detected. Some features are not
supported by SmartStart. This can be caused by
missing wire connections or module hardware limitation.
Refer to "Installation" on page 8 to check the
connections.
GWR (Status) command received.
Used to ensure the module has received the remote
start message and has enabled the remote start
runtime. Commands can come from RF or D2D.
IGNITION ON command received.
Used to ensure the module received the ignition
command.
START ON command received.
Used to ensure the module received the start command.
LOCK command received.
UNLOCK command received.
TRUNK command received.
If the bypass module fails to flash, it means the module
did not receive the signal.
Module Programming
Module Programming - Error Codes
External Module Synchronization
Active Ground When Running (Status)
D2D & W2W Commands
Solid red
Solid green
x 3 secs then
flashes
orange quickly
Flashes orange
slowly
Flashes green
quickly
Solid green
x 3 secs
Flashes
green
Flashes
green quickly
Off
(Flashes red,
red, then
orange) x 10
Flashes
red &
orange
Flashes
orange x 3
Flashes
orange x 2
Flashes
orange x 1
Flashes red
x 2
Flashes red
x 3
LED
Status
Description
Troubleshooting
Off
Module has no power.
Check the power connections.
Solid red
Start of programming is normal
If the LED is red after the ignition is ON, check for CAN-High
and CAN-Low connections as the ignition is not seen on
CAN.
Flashes green fast
Normal. CAN programmed and waiting for
bypass programming.
Normal operation
Flashes orange
slowly
Normal. Waiting for offline key2go
programming.
Solid green for 3
seconds with a quick
orange flash.
Module successfully programmed or is
already programmed.
Normal operation
Solid green for 3
seconds.
Module successfully programmed.
Normal operation
Module programming - Error codes
Flashes red x2
CAN not detected.
Check the Tan - Tan/Black wire connections. Wake up the
data bus by turning the ignition on and try again.
Flashes red x3
Bypass data not detected.
Check the bypass line connection, make sure there is a
continuity between the 2 sides of the cut and turn the ignition
ON. Make sure the battery was removed when turning the
ignition ON.
External Module Synchronisation
Flashes red, red,
then orange x 10
OBDII feature not supported.
Diagnostic data bus not detected. Some features are not
supported by SmartStart. This can be caused by missing
wire connections or module hardware limitation. Refer to
the wiring installation section to check the connections.
Active Ground While Running
Flashes green
GROUND OUT ON (GWR) command
received.
Otherwise, the Ground While Running (status) signal
was lost or was never received by the module.
Commands can come from RF, D2D or W2W.
Flashes red &
orange
IGNITION ON command received.
Otherwise, the ignition signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
Flashes green
quickly
START ON command received.
Otherwise, the start signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
D2D and W2W Commands
Flashes orange x 1
LOCK command received.
Flashes orange x 2
UNLOCK command received.
Flashes orange x 3
TRUNK command received.
Module programming - Firmware specific
Commands can come from RF, D2D or W2W.
Solid
OFF
Flashes
Flashes
Solid and
quick flash
Solid
Flashes
red x2
Flashes
red x3
Flashes
red, red,
orange x10
Flashes
green
Flashes
green
Flashes
orange x1
Flashes
orange x1
Flashes
orange x1
Flashes
orange x1
Flashes
orange x2
Flashes
orange x3
Flashes red