Xpresskit DBALL Installation Manual - page 11
Rev.: 20160610
Platform: DBALL/DBALL2
Firmware:
CHRYSLER7
© 2016 Directed. All rights reserved.
To enter feature programming routine
-
Turn the ignition ON, then OFF.
-
Within 5 seconds, press and HOLD the programming button until the LED turns ON orange (after 3 seconds). Release the
Programming button.
-
The LED will flash green once slowly to indicate the feature number is 1. After a short delay, the LED flashes red rapidly to indicate
the current option of feature 1 (i.e. 1x green followed by 1x red indicates feature 1 is set to option 1). The flashing sequence will repeat
until a new command is entered.
Changing feature options
-
Press the lock/arm or unlock/disarm button on aftermarket transmitter to change the option of the selected feature.
-
The LED flashes red rapidly the number of times equal to the current option number. After a short delay, the LED flashes green slowly
the number of times to indicate the current feature. The flashing sequence will repeat until a new command is entered.
Accessing another feature
-
Press and release the programming button a number of times to advance from the current feature to the next desired feature.
-
The LED flashes green slowly the number of times equal to the feature number. After a short delay, the LED flashes red rapidly to
indicate the current option of the current feature. The flashing sequence will repeat until a new command is entered.
When the maximum number of features or options is reached, the LED will start flashing again from the first feature or option.
Once a feature is programmed
-
Other features can be programmed.
-
The feature programming can be exited.
Exiting feature programming
-
No activity for 30 seconds; after 30 seconds, the LED will turn ON orange for 2 seconds to confirm the end of the programming
sequence.
OR
-
Press and HOLD the programming button for 3 seconds. After 3 seconds, the LED will turn ON orange for 2 seconds to confirm the
end of the programming sequence.
Feature Programming
Programming
Button
Page 11
LED
Status
Description
Troubleshooting
Off
Module has no power.
Check the power connections.
Solid red
Start of programming is normal
If the LED is red after the ignition is ON, check for CAN-High
and CAN-Low connections as the ignition is not seen on
CAN.
Flashes green fast
Normal. CAN programmed and waiting for
bypass programming.
Normal operation
Flashes orange
slowly
Normal. Waiting for offline key2go
programming.
Solid green for 3
seconds with a quick
orange flash.
Module successfully programmed or is
already programmed.
Normal operation
Solid green for 3
seconds.
Module successfully programmed.
Normal operation
Module programming - Error codes
Flashes red x2
CAN not detected.
Check the Tan - Tan/Black wire connections. Wake up the
data bus by turning the ignition on and try again.
Flashes red x3
Bypass data not detected.
Check the bypass line connection, make sure there is a
continuity between the 2 sides of the cut and turn the ignition
ON. Make sure the battery was removed when turning the
ignition ON.
External Module Synchronisation
Flashes red, red,
then orange x 10
OBDII feature not supported.
Diagnostic data bus not detected. Some features are not
supported by SmartStart. This can be caused by missing
wire connections or module hardware limitation. Refer to
the wiring installation section to check the connections.
Active Ground While Running
Flashes green
GROUND OUT ON (GWR) command
received.
Otherwise, the Ground While Running (status) signal
was lost or was never received by the module.
Commands can come from RF, D2D or W2W.
Flashes red &
orange
IGNITION ON command received.
Otherwise, the ignition signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
Flashes green
quickly
START ON command received.
Otherwise, the start signal was not received by the
module. In a W2W install, it will show only if the ignition
input wire is used.
D2D and W2W Commands
Flashes orange x 1
LOCK command received.
Flashes orange x 2
UNLOCK command received.
Flashes orange x 3
TRUNK command received.
Module programming - Firmware specific
Commands can come from RF, D2D or W2W.
Solid
OFF
Flashes
Flashes
Solid and
quick flash
Solid
Flashes
red x2
Flashes
red x3
Flashes
red, red,
orange x10
Flashes
green
Flashes
green
Flashes
orange x1
Flashes
orange x1
Flashes
orange x1
Flashes
orange x1
Flashes
orange x2
Flashes
orange x3
Flashes red
& orange