Summary of Interactive 2000 PowerCharger

  • Page 1

    One wor ld. O ne s mar t ch oice . ™ owner’s manual dual 2722 a7595-0231 rev j charger / power supply ® battery system approved copy.

  • Page 2

    Table of contents 1 introduction features safeguards grounding/earthing 2-3 operation charging applications three stage charging methodology 3-4 led indications lcd indications 5 ddm (diagnostic/discharge module) to operate the ddm 6 “autocal” feature operation as dc camera supply from mains fcc not...

  • Page 3

    1 introduction the dual 2722 is a simultaneous 2 position interactive ® 2000 powercharger ® fast charger with 70 watt dc camera power supply. It incorporates all of the logic series ® circuits that are employed in every anton/bauer ® charger. The interactive ® charge programming provides all charge ...

  • Page 4

    2 operation charging as with all anton/bauer chargers, charging with dual 2722 is fully automatic. Mount any digital logic series ® or logic series ® battery to the dual 2722 and it will automatically determine the appropriate charge routine and execute it. Applications the dual 2722 will charge any...

  • Page 5

    3 three stage charging methodology (cont.) on the condition of the battery. The stage two charge for dionic ® batteries reduces current automatically as the battery charges maintaining the lithium ion cells at a safe voltage level. A battery will typically leave stage two in 2-4 hours under average ...

  • Page 6

    4 lcd indications each powercharger’s ® liquid crystal display (lcd) will display the status of each battery, as well as, important powercharger ® operating indications. The following information explains the indications which appear in the lcd. The levels of the lcd display on each powercharger ® c...

  • Page 7

    5 ddm (diagnostic/discharge module) a standard feature with the dual 2722, the ddm completes a battery management system, capable of testing battery capacity and identifying battery anomalies before they appear in the field. The ddm will perform a standard or a 24 hour test. The standard test is a f...

  • Page 8

    6 fcc notice this equipment has been tested and found to comply with the limits for a class a digital device pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This ...

  • Page 9

    7 limited warranty this three (3) year limited warranty for the battery product specified in this document (“product”) is given by anton/bauer, inc. (“anton/bau- er”), 14 progress drive, shelton, connecticut 06484. If you (the pur- chaser of the product from anton/bauer, or the person for whom the p...

  • Page 10

    Anton/bauer a vitec group brand the following are trademarks of anton/bauer, inc.: anton/bauer, anton/bauer logo and parallelogram design, aspekt, automatique, datatap, dionic, elipz, egripz, elightz, essentialz, gold mount, hubz, hytron, impac, interactive and design, lifesaver, logic series, logic...