    Table of contents important read and understand this manual before operation .................................................................... 1 introduction.............................................................................. 2 features .....................................................

  • Page 3: Important

    1 important read and understand this manual before operation the interactive 2000 dionic 90 battery lithium ion chemistry delivers a higher power to weight ratio than nicd & nimh. However, all lithium ion batteries have more sensitive charging and discharging parameters and require longer charge tim...

  • Page 4: Introduction

    2 introduction the development of this new dionic 90 battery system has been made possible through the incorporation of the pioneering interactive technology of the anton/bauer digital system with the very latest lithium ion cell formulations. Each dionic 90 battery features an on-board “fuel comput...

  • Page 5: Features

    3 features 1. Microprocessor fuel computer - accurately monitors the energy in the battery with programs that take into account battery age, self discharge, charge/discharge rate, operating conditions and previously experienced charge/discharge cycles. The dionic 90 battery constantly “learns” its p...

  • Page 6: Charging Dionic 90 Batteries

    4 charging dionic 90 batteries • do not attempt to charge this battery with any charger other than the anton/bauer interactive 2000 or t series chargers specified in this manual. •allow the battery to reach a steady green (lifesaver ® ) mode before using for the first time. Please read the individua...

  • Page 7: Charge Level Led Indicators

    5 nominal charge times for dionic 90 charge level led indicators 90% flashing green 100% steady green dual 2722 (2 batteries simultaneously) 2hrs. 3hrs. Interactive 2000 powercharger (quad/dual – 2702/2701/2700) (quad/dual – 2401/2400) 2 hrs. 3 hrs. T2 (2 batteries simultaneously) 2hrs. 3hrs. Tandem...

  • Page 8

    6 the dionic 90 features an all new “realtime” lcd display providing on-the-fly remaining run time estimates in 15 minute increments as well as simultaneously providing remaining capacity information using the traditional “fuel gauge” approach. No special adapters or set up is required. Realtime aut...

  • Page 9

    7 -the large numbers 1, 2 or 3 indicate remaining hours under current load (only one number will display at any one time) -the pie chart numbers (15, 30, 45, or 60) indicate remaining minutes under current load. -the interactive segment indicates a fully charged battery verified by charger communica...

  • Page 10

    8 if the side bars (only)flash and other icons are lit and not flashing, this indicates the battery has requested to be fully charged and discharged in order to update its “learned capacity”. This “learning” should typically occur during normal equipment operation. However, if the battery has not be...

  • Page 11: Overcurrent Indication

    9 realtime display indications • when the dionic battery is being charged remaining runtime is not displayed. • remaining run time is calculated using the present available battery capacity and a constantly updated accurate measurement of the present load on the battery. • if no load is detected, or...

  • Page 12: Lcd Icon’S Indication

    10 • when the battery is completely discharged the lcd will flash the 15 minute icon and the ‘res’ bar until the battery is returned to a charger. • if the protection electronics detect a low battery voltage condition (any one cell reaches roughly 2.5vdc or approximately 10v battery voltage), the lc...

  • Page 13: Operating Guidelines

    11 operating guidelines 1. Keep batteries cool or at room temperatures whenever possible. Sustained elevated temperatures are the primary reason for premature failure of lithium ion batteries: a. Charging - charge batteries at room temperature. In warm climates keep chargers in air conditioned rooms...

  • Page 14

    12 4. Low voltage batteries can also be caused by allowing batteries to remain off the charger for extended periods causing the lcd display to be blank, indicating that the electronic circuitry has removed all load from the battery cells – including the display. In the case that the battery is in a ...

  • Page 15: Service

    13 service in the event a dionic 90 battery fails to deliver acceptable performance, it must be returned to the anton/bauer. No other facility is qualified and equipped to service the interactive 2000 dionic 90 batteries and calibrate the electronic components and sensors. Any attempt by the user or...

  • Page 16: Precautions

    14 precautions 1. Do not expose this battery to high temperatures (above 50°c/120°f). This includes storage in direct sunlight , in cars in hot weather, or in close proximity to heating devices. This may cause electrolyte leakage, impaired performance and shortening of battery service life. 2. When ...

  • Page 17: Output Voltage

    15 dionic 90 battery specifications output voltage 14.4v nominal 12.4 ~ 16.8v operating capacity (cell capacity) 90 wh nominal (6.3 ah rated) fuse internal 8amp recommended operation 15 - 50 watts 1 (maximum discharge rate) (90 watts) 2 typical run-time @ 20w - 4 ½ hrs. @ 25w - 3 ½ hrs. @ 40w - 2 ¼ ...

  • Page 18

    16 limited warranty this warranty for the battery product specified in this document (“product”) is given by anton/bauer, inc. (“anton/bauer”), 14 progress drive, shelton, connecticut 06484. If you (the purchaser of the product from anton/bauer, or the person for whom the product was purchased, if i...

  • Page 19: Material Regulation).

    17 dangerous goods regulations 49cfr parts 100-185, air transport association (iata) and the international civil aviation organization (icao) regulations apply to all lithium ion battery transport. Air transportation declaration anton/bauer, inc. Declares that the dionic 90 lithium ion battery pack ...

  • Page 20: Www.Antonbauer.Com

    7595-0243 rev m the power behind the best cameras capturing the best images in the world. Sm the following are trademarks of anton/bauer, inc.: acs, adm, all chem, anton/bauer, anton/bauer logo and parallelogram design, automatique, egripz, elightz, elipz, essentialz, datatap, dionic, gold mount, hy...