Baseline 225 Manual - Rounding
14
Rounding
When the machine is switched on its default setting is to show the unbalance to the nearest five
grams (rounding up or down as necessary) or to the nearest 1/4 ounce if data output in ounces has
been set.
In this default setting, the first 4 grams are not displayed since they are regarded as below the
operational threshold (the „Thr‟ LED will turn off) and the unbalance will be shown to the last gram
(or to the last 1/10 of an ounce if this display made is active).
Each time the key is press, the machine toggles between threshold ON and threshold OFF.
Attention
Never raise up the wheel cover before the wheel has come to a stop.
(For models with wheel cover only)
If, due to a fault in the machine, the wheel keeps spinning permanently, switch off the machine at the
master switch or by unplugging the plug from the power supply.
Then wait until the wheel stops, or apply the brake with the pedal.
Balancing programs
Before starting a balancing cycle:
Mount the wheel on the shaft using the appropriate flange
Remove any balancing weights, stones, dirt or other foreign bodies from the wheel
Input wheel data correctly.
Dynamic balancing (standard)
Press the keys until the LED for DYN balancing program lights.
Press
to confirm your choice.
Dynamic balancing mode is the default setting when the machine is switched on.
Input the wheel data correctly.
Spin the wheel by pressing the start button on the panel.
For best balancing results do not rush the machine while it is processing the unbalance signals.
Wait for the beep signaling that the data processing has been completed.
Brake the wheel with the pedal brake (E, pic.4) (wheel stops automatically on models with
automatic brake.)
The unbalance weights will be shown on display A and B (pic.4a) for the inside and outside
planes respectively.
Choose the first side you intend to balance and turn the lights and you will also hear a