Cabletron Systems SmartSwitch 1800 User Manual - page 133
Configuring SNA
9-7
1
Set
Autocall
to
Y
for TPADs and
N
for HPADs.
2
If the PU will be used for SDLC-LLC2 conversion (at the local node, or at a remote node
via a logical or physical X.25 port), this must be
Y
.
3
In multiples of 4.
4
In Token Ring format.
5
Will override the value configured for the same parameter in the Node Defaults file, with
two exceptions—if
0
is configured in Port Configuration for
Priori ty
or
Bandwidth Al lo-
cation G roup
, the value in Node Defaults will apply.
6
Must be less than the value for
T1
to ensure that the remote link station will receive the
delayed acknowledgment before
T1
expires.
Port Type
specifies the protocol the port will support. Selecting this parameter will display a list
of all serial protocols loaded in the device.
Name
is used to identify the port to some manager devices.
Table 9-2 SNA Port PU Parameters
Parameter
Valid Values
Default Value
PU Name
up to 10 characters
none
Local Subscriber ID
0–15 characters
none
Remote Subscriber ID
0–15 characters
none
Maxdata
(Max I-Frm bytes/ frame)
25–4105
265
Autocall
Y/ N
1
N
Autocall Retry Time
(sec)
15–255
60
Autocall Retry Count
0–255
0
(indefinite)
Istatus
Active, I nactive
Acti ve
LPDA Resource ID
0–255
0
LLC2 Connection
Y/ N
2
N
L2DatMode
Two-way Alternate,
Two-way Si multaneous
Two-way Al ternate
LLC2 Parameters
Local SAP Address
0–fc
(hex)
3
04
Local MAC Address
0–ffffffffffff
4
000000000000
IDBLK
0–fff
000
IDNUM
0–fffff
00000
T1
(100 msec)
5
0–250
10
T2
(msec)
5
100–5000
6
100
Ti
(sec)
5
1–50
30
N3
5
1–127
1
Tw
5
1–127
1
N2
5
0–255
8
Priority
5
0–9
0
Bandw idth Al location G roup
5
0–16
0
Suppr ess XIDs
Y/ N
N