Cabletron Systems SmartSwitch 1800 User Manual - page 224
14-8
SmartSwitch 1800 4. 0 User G uide, Rev 01
1
Y
for new interfaces,
N
for interfaces already configured when the current release of
SmartSwitch 1800 software is installed.
2
255.255.255.255
is valid only on a point-to-point interface.
3
The default value of
Network Mask
will be configured automatically, to reflect the
appropriate address class, after the
Source IP Address
is specified..
If the interface is
configured as unnumbered (and, therefore, no
Source I P Address
is configured), the
default value of
Network Mask
will be taken from the numbered interface that is
assigned.
If a
Source IP Address
is specified/changed, the
Network Mask
will automatically change to a default value appropriate
for the new address. For this reason, configure the
Source
IP Address
first, then the
Network Mask
.
4
These addresses must also be configured in Subscriber records (described on page 8-20),
and cannot contain wildcards. In the record for the Source Subscriber, do not configure
any Routing Path. In the record for the Destination Subscriber, configure
1st Routing
Path
as the node, RLP (only if FRX6000 or FRM), and X.25 port that will be used for
the physical interface. (On an FRX6000 or FRM, that RLP does not need to be the same
one that has IP installed.)
Table 14-3 X.25 IP Interface Parameters
Parameter
Valid Values
Default Value
Maximum Transmission Unit
1–4096
4096
Routi ng Metri c Count
0–255
0
ICMP Redi rects
Y/N
Y
RIP Support
0
(Enabled),
1
(Rcv only),
2
(Disabled)
0
(Enabled)
RIP Flash Updates
(sec)
5–300
10
RIP Ful l Updates
(sec)
10–300
30
Pr iority
0–9
5
Bandwi dth Allocation Group
1–16
1
Interface Type
X.25
n/a
Desti nation IP Address
1. 0.0.0–223.255.255.255
none
Unnumbered Interface
Y/N
see note
1
Source I P Address
1. 0.0.0–223.255.255.255
none
Network Mask
255.0.0.0–255.255.255.255
2
255.0.0.0
3
Source Subscr iber
valid subscriber address
4
none
Desti nation Subscriber
valid subscriber address
4
none
SVC Retry Ti mer
(sec)
5–60
20
SVC Idle Timer
(min)
0–5
1
Max VCs to Establi sh
1–8
1
PVC Connection
Y/N
N