Cabletron Systems SmartSwitch 1800 User Manual - page 181
Configuring Async Ports
12-3
PAD Profile Parameters
The numbers preceding the parameter names correspond to CCITT
X.3. Also, the default values make up CCITT profile 90.
When specifying characters that will perform functions (i.e.,
Data Forwarding
or
Character Delete
), be sure to specify these
as different characters
Profile Description
is used simply as an identifier. It is not an X.3 parameter.
01, PAD Recall
allows the user's device to initiate an escape from data transfer or connection in
progress state in order to send PAD command signals. Values (can be added) are:
0
= escape is not allowed.
1
= escape will be initiated by
[Ctrl] [P]
(
1/0
),
Data Link Escape
.
32–126
= escape will be initiated by the character defined by this number.
Table 12-1 Async PAD Profile Parameters
Parameter
Valid Values
Default Value
Profile Description
1–31 uppercase chars.
none
01, PAD Recall
0–126
1
02, Echo
0
(no) /
1
(yes)
1
03, Data Forwarding Char
0–127
126
04, Idle Timer Delay
( sec)
0–255
0
05, Ancill ary Device Control
0–2
1
06, PAD Servi ce Signal
0–15
1
07, Receive Break Signal
0–31
2
08, Discard O utput
0
(no) /
1
(yes)
0
09, Paddi ng After
0–255
(characters)
0
10, Line Fol di ng
0–255
0
11, Speed
n/a–determined in Port configration
12, Flow Contr ol
0
(no) /
1
(yes)
1
13, Insert
0–7
0
14, Paddi ng after
0–255
(characters)
0
15, Editing
0
(no) /
1
(yes)
0
16, Character Delete
0–127
127
17, Line Delete
0–127
24
18, Line Di splay
0–127
18
19, Edit Service Signal
0–126
1
20, Echo Mask
0–255
0
21, Parity
0–3
0
22, Page Wait
0–255
(linefeeds)
0