Cabletron Systems SmartSwitch 1800 User Manual - page 207
Configuring Voice
13-9
Voice Port Parameters
1
0
= disable,
1
= enable,
2–255
= number of seconds tone will be generated.
2
Valid only if
Interface
is
E&M
.
3
The number of digits used as an auto-dial number. ( The parameter
Speed Map Dial
Di gits
is configured in Voice System-Level Parameters.)
4
If you set
Source of Extended Di gi ts
to
Map
, the
Dial Timer
value will automatically be
Table 13-4 Voice Port Parameters
Parameter
Valid Values
Default Value
Bl ocked Port Flag
Y/N
N
Rate
4.8, 8, 32, 64
Kbps
8
Kbps
DTMF Detecti on
1–255
1
1
Ti med E Timer
0–255
(seconds)
2
3
Input Level
see explanation
0
(dB)
Output Level
see explanation
-4
(dB)
In Hunt Group
irrelevant—not currently supported
N
SLT Time-out
1–99
(seconds)
30
Li nk Down Busy
Y/N
Y
Fax Supported
Y/N
Y
Telephony Interface Type
OPX, SLT, E&M, AC15
O PX
Interface
Depends on setting of
Telephony
Inter face Type
—see explanation
Loop Start
Jitter
10–255
(msec, in 5-ms increments)
80
Call Ti mer
1–30
(seconds)
5
Long Dial Pr efix
see explanation
*
(asterisk)
Suppr ession
1–5
(
1
= no suppression)
2
Auto Dial Parameters
Auto Dial
Y/N
N
Auto Dial Num ber
number of digits configured for
Speed Map Dial Digits
3
none
Auto Poll
Y/N
N
Auto Poll Timer
5–30
(seconds)
10
Enhanced Dialing Parameters
Di al Ti mer
(sec)
0–10
(
0
= no time limit)
0
4
Source of Extended Digits
Map, User
Map
4
# of Leading Digits to Delete
0–4
0
Forw ard Del ay
0–40
(0.25 sec increments)
2
(0.5 sec)
Forw arded Di gi t Type
DTMF, Pul se
DTMF
Forw arded Output Digits
None, All, Ext
None
Make/Break Ratio
Make:
20–80
(in increments of 2)
Break:
80–20
(in increments of 2)
34
66
DTMF ON Duration
30–1000 ms
100
DTMF OFF Duration
30–1000 ms
100
Tone Type
DTMF, MF
DTMF