Cabletron Systems SmartSwitch 1800 User Manual - page 371
Syst em Events
22-23
541.
DLCI “n” Frame Relay Header Invalid
Severity:
3
Meaning:
The header contained an invalid DLCI.
Action:
Check the configuration record for the port.
542.
DLCI “n” PVC does not exist
Severity:
3
Meaning:
Self-explanatory.
Action:
Create a PVC record.
543.
DLCI “n” Frame Discarded - CIR
Severity:
3
Meaning:
A frame was discarded, probably because the excess burst size (B
E
)
was exceeded.
Action:
The frame must be resent.
545.
DLCI “n” frame relay PVC deleted
Severity:
4
Meaning:
Self-explanatory.
Action:
None.
546.
DLCI “n” frame relay PVC connected
Severity:
4
Meaning:
Self-explanatory.
Action:
None.
547.
DLCI “n” Data Received on Inactive PVC
Severity:
3
Meaning:
One end of the PVC is probably not up.
Action:
Check both ends of the PVC.
548.
DLCI “n” No STATUS ENQ Received
Severity:
3
Meaning:
No Status Enquiry was received when one was expected.
Action:
Check the remote device.
561.
LLC Interface File Upd:LLC2IPAR.DAT
Severity:
4
Meaning:
The LLC2 Interface file has been updated.
Action:
None.